Share:

PARKS HIGHWAY over HURRICANE GULCH

Map

Coordinates:
+63.01427, -149.59070
63°00'51" N, 149°35'27" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:PARKS HIGHWAY over HURRICANE GULCH
Structure number:0258
Location:MILE POINT 139.7
Purpose:Carries highway over waterway
Route classification:Principal Arterial - Interstate (Rural) [01]
Length of largest span:407.2 ft. [124.1 m]
Total length:558.4 ft. [170.2 m]
Roadway width between curbs:31.5 ft. [9.6 m]
Deck width edge-to-edge:34.5 ft. [10.5 m]
Owner:State Highway Agency [01]
Year built:1971
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Main span material:Steel [3]
Main span design:Arch - Deck [11]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: June 2018

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:1,078 [as of 2017]
Truck traffic:21% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Bridge foundations (including piles) on dry land well above flood water elevations. [9]
Sufficiency rating:68.0

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
June 2018FairSatisfactorySatisfactorySatisfactory107868.0
June 2016FairSatisfactorySatisfactorySatisfactory111767.5
June 2014FairSatisfactorySatisfactorySatisfactory130866.9
June 2012FairSatisfactorySatisfactorySatisfactory128266.9
June 2010FairSatisfactorySatisfactorySatisfactory114971.8
July 2008FairSatisfactorySatisfactorySatisfactory168070.8
June 2006FairSatisfactoryFairFair128259.5
July 2004FairFairFairFair110058.5
August 2002FairFairFairFair100759.0
August 2000FairFairFairFair100759.0
August 1998FairFairFairFair92561.2
September 1996FairFairGoodGood89575.5
May 1994GoodGoodGoodGood83781.4
September 1992GoodGoodGoodGood90080.9
August 1990GoodGoodGoodGood90080.9

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.70056014000
Steel Protective Coatingsq. ft.6,5004,2243256501,301
Steel Stringerlinear ft.2,0901,67241800
Steel Protective Coatingsq. ft.12,5108,1336251,2512,501
Deck
Reinforced Concrete Decksq. ft.19,21018,25096000
Wearing Surfacessq. ft.17,59016,71187900
Superstructure
Steel Archlinear ft.81032448600
Steel Protective Coatingsq. ft.18,2305,46691291210,940
Steel Floor Beamlinear ft.3803235700
Steel Protective Coatingsq. ft.2,7502,062138138412
Steel Pin or Pin & Hangar Assemblyeach36220140
Steel Protective Coatingsq. ft.70444418
Substructure
Steel Columneach2202020
Steel Protective Coatingsq. ft.1,600164319319798
Reinforced Concrete Abutmentlinear ft.70382840
Steel Pier Caplinear ft.6206200
Steel Protective Coatingsq. ft.5201585252258
Joints
Assembly with Sealeach70147742
Bearings
Movable Bearingeach20200
Steel Protective Coatingsq. ft.2000020
Fixed Bearingeach20200
Steel Protective Coatingsq. ft.2000020
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.1,1208961121120
Steel Protective Coatingsq. ft.6,7006,03006700