Share:

PARKS HIGHWAY over PASS CREEK

Map

Coordinates:
+63.37579, -148.95041
63°22'33" N, 148°57'01" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:PARKS HIGHWAY over PASS CREEK
Structure number:0293
Location:MILE POINT 172.7
Purpose:Carries highway over waterway
Route classification:Principal Arterial - Interstate (Rural) [01]
Length of largest span:65.0 ft. [19.8 m]
Total length:131.6 ft. [40.1 m]
Roadway width between curbs:29.9 ft. [9.1 m]
Deck width edge-to-edge:35.1 ft. [10.7 m]
Owner:State Highway Agency [01]
Year built:1965
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:2
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: June 2018

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:1,211 [as of 2017]
Truck traffic:26% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:67.5

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
June 2018FairGoodSatisfactorySatisfactory121167.5
June 2016FairSatisfactorySatisfactorySatisfactory122969.7
June 2014FairSatisfactorySatisfactorySatisfactory189569.7
June 2012FairSatisfactorySatisfactorySatisfactory179769.7
June 2010FairSatisfactorySatisfactorySatisfactory159469.7
July 2008FairSatisfactorySatisfactorySatisfactory164469.7
June 2006FairSatisfactorySatisfactorySatisfactory138468.0
July 2004PoorPoorFairFair122554.0
August 2002PoorPoorFairFair136154.0
August 2000FairFairFairFair136156.0
August 1998FairFairFairFair130056.0
September 1996FairFairGoodGood113167.6
May 1994FairSatisfactoryGoodGood121872.7
September 1992FairSatisfactoryGoodGood90076.5
August 1990FairSatisfactoryGoodGood90076.5

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.6505856500
Steel Protective Coatingsq. ft.5,6303,3785631,126563
Deck
Reinforced Concrete Decksq. ft.4,6404,40823200
Wearing Surfacessq. ft.3,9503953953952,765
Substructure
Reinforced Concrete Pier Walllinear ft.30151500
Reinforced Concrete Abutmentlinear ft.7062800
Steel Pileeach60060
Steel Protective Coatingsq. ft.4401764488132
Reinforced Concrete Pier Caplinear ft.3030000
Joints
Pourable Jointlinear ft.4040000
Bearings
Movable Bearingeach50500
Steel Protective Coatingsq. ft.50002525
Fixed Bearingeach1501500
Steel Protective Coatingsq. ft.150007575
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.260687810410
Steel Protective Coatingsq. ft.1,5801,580000