Share:

WILLIAMSPORT/PILE over CHINKELYES CREEK

Map

Coordinates:
+59.70381, -153.71204
59°42'14" N, 153°42'43" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:WILLIAMSPORT/PILE over CHINKELYES CREEK
Structure number:0484
Location:MILE POINT 3.5
Purpose:Carries highway over waterway
Route classification:Minor Collector (Rural) [08]
Length of largest span:140.1 ft. [42.7 m]
Total length:140.1 ft. [42.7 m]
Roadway width between curbs:13.8 ft. [4.2 m]
Deck width edge-to-edge:15.7 ft. [4.8 m]
Owner:State Highway Agency [01]
Year built:2002
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Main span material:Steel [3]
Main span design:Truss - Thru [10]
Deck type:Wood or Timber [8]

Latest Available Inspection: July 2018

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:19 [as of 2017]
Truck traffic:24% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Bridge is scour critical; bridge foundations determined to be unstable. [3]
Sufficiency rating:57.3

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
July 2018FairGoodSatisfactoryFair1957.3
July 2016FairGoodSatisfactoryFair2056.2
July 2014GoodGoodGoodGood2067.2
July 2012GoodGoodGoodGood2067.9
July 2010GoodGoodGoodGood1046.8
May 2008GoodGoodGoodGood1046.8
June 2006GoodGoodGoodGood2023.4
June 2004GoodVery GoodVery GoodGood2023.4
March 2003GoodVery GoodVery GoodGood1578.1
July 2000----1531.3
June 1998----1531.3
June 1996----1031.5
June 1995----1031.6
July 1993-----32.0
August 1991-----32.0

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Stringerlinear ft.2,9402,64629400
Steel Protective Coatingsq. ft.2,9401,4401,50000
Steel Trusslinear ft.5605045600
Steel Protective Coatingsq. ft.2,8001,120840700140
Steel Floor Beamlinear ft.59044414600
Steel Protective Coatingsq. ft.1,4601,09436600
Substructure
Timber Abutmentlinear ft.4203930
Deck
Timber Decksq. ft.1,95011,94900
Bearings
Movable Bearingeach40040
Steel Protective Coatingsq. ft.4004000
Fixed Bearingeach40400
Steel Protective Coatingsq. ft.4004000