Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:16TH ST NO. over VILLAGE CREEK
Structure number:000287
Location:16TH ST * VILLAGE CK
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Local (Urban) [19]
Length of largest span:36.1 ft. [11.0 m]
Total length:71.9 ft. [21.9 m]
Roadway width between curbs:40.4 ft. [12.3 m]
Deck width edge-to-edge:60.0 ft. [18.3 m]
Owner:City or Municipal Highway Agency [04]
Year built:1925
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Number of main spans:2
Main spans material:Concrete [1]
Main spans design:Tee beam [04]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: August 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:10,000 [as of 2016]
Truck traffic:5% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Operating rating:47.9 tons [43.5 metric tons]
Inventory rating:36.0 tons [32.7 metric tons]
Sufficiency rating:66.6
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$1,328,000

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
August 201666.6FairFairFairSatisfactory-10000
August 201466.6FairFairFairSatisfactory-10000
October 201266.6FairFairFairSatisfactory-10000
October 201059.1FairFairFairSatisfactory-10000
October 200859.1FairFairFairSatisfactory-10000
April 200659.1FairFairFairSatisfactory-10000
November 200459.1FairFairFairSatisfactory-10000
July 200259.1FairFairFairSatisfactory-10000
August 200059.1FairFairFairSatisfactory-10000
October 199859.1FairFairFairSatisfactory-10000
December 199670.2FairFairSatisfactorySatisfactory-10000
December 199271.4FairSatisfactorySatisfactorySatisfactory-10000