Share:

COALBURG ROAD over 5 MILE CREEK

Map

Coordinates:
+33.60616, -86.85429
33°36'22" N, 86°51'15" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:COALBURG ROAD over 5 MILE CREEK
Structure number:004460
Location:COALBURG RD * 5-MILE CK
Purpose:Carries highway over waterway
Route classification:Local (Urban) [19]
Length of largest span:34.1 ft. [10.4 m]
Total length:239.5 ft. [73.0 m]
Roadway width between curbs:23.6 ft. [7.2 m]
Deck width edge-to-edge:27.6 ft. [8.4 m]
Owner:City or Municipal Highway Agency [04]
Year built:1952
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 13.5 / H 15 [2]
Number of main spans:7
Main spans material:Concrete [1]
Main spans design:Tee beam [04]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: November 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:1,500 [as of 2016]
Truck traffic:20% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Basically intolerable requiring high priority of corrrective action [3]
Water adequacy appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Operating rating:43.7 tons [39.7 metric tons]
Inventory rating:26.3 tons [23.9 metric tons]
Sufficiency rating:56.1
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$1,696,000

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
November 201656.1FairFairFairFairFO1500
November 201479.7FairSatisfactorySatisfactorySatisfactoryFO1500
November 201279.7FairGoodGoodSatisfactoryFO1500
November 201079.7FairGoodGoodSatisfactoryFO1500
November 200879.7FairGoodGoodSatisfactoryFO1500
December 200678.8FairGoodGoodSatisfactory-1500
December 200478.8FairGoodGoodSatisfactory-1500
August 200279.2FairGoodGoodSatisfactory-1000
December 200079.2FairGoodGoodSatisfactory-1000
November 199885.4FairGoodGoodSatisfactory-700
October 199685.4FairGoodGoodSatisfactory-700
December 199484.4FairGoodGoodSatisfactory-700
December 199284.4FairGoodGoodSatisfactory-700