Share:

SR 239 MP 4.371 over STREAM

Map

Coordinates:
+31.88355, -85.49747
31°53'01" N, 85°29'51" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:SR 239 MP 4.371 over STREAM
Structure number:004694
Old structure number:000002390300230 (from 1992 edition)
Location:2.3 MI. NORTH OF CLAYTON
Purpose:Carries highway over waterway
Route classification:Major Collector (Rural) [07]
Length of largest span:14.1 ft. [4.3 m]
Total length:43.0 ft. [13.1 m]
Owner:State Highway Agency [01]
Year built:1953
Year reconstructed:1992
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 13.5 / H 15 [2]
Number of main spans:3
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Not applicable [N]

Latest Available Inspection: June 2017

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:990 [as of 2013]
Truck traffic:4% of total traffic
Structural appraisal:Better than present minimum criteria [7]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Culvert condition:Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:99.2
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$554,000

Previous Inspections

DateConditionCulvert ConditionADTSuff. Rating
June 2017Good7 out of 1099099.2
June 2015Good7 out of 1099099.2
June 2013Good7 out of 1099099.2
June 2011Good7 out of 10169098.8
June 2009Good7 out of 10150098.9
June 2007Good7 out of 10133099.0
June 2005Good7 out of 10103077.9
June 2003Good7 out of 1099077.9
June 2001Good7 out of 1099077.7
June 1999Good7 out of 10112077.7
June 1997Good7 out of 10112077.7
June 1995Good7 out of 10102077.6
July 1993Good7 out of 10105077.6
November 1991Good7 out of 10111062.3