GROVELAND DR. over HOLY WATER CREEK
Map
Coordinates:
+32.39698, -86.2187332°23'49" N, 86°13'07" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | GROVELAND DR. over HOLY WATER CREEK |
Structure number: | 008671 |
Old structure number: | 0000000651M0010 (from 1992 edition) |
Location: | 0.2 MI E OF W CITY LIMITS |
Purpose: | Carries highway and pedestrian walkway over waterway |
Route classification: | Local (Urban) [19] |
Length of largest span: | 34.1 ft. [10.4 m] |
Total length: | 67.9 ft. [20.7 m] |
Roadway width between curbs: | 30.8 ft. [9.4 m] |
Deck width edge-to-edge: | 40.4 ft. [12.3 m] |
Owner: | City or Municipal Highway Agency [04] |
Year built: | 1965 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | M 13.5 / H 15 [2] |
Number of main spans: | 2 |
Main spans material: | Concrete [1] |
Main spans design: | Channel beam [22] |
Deck type: | Concrete Precast Panels [2] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: September 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 590 [as of 1990] |
Truck traffic: | 1% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Equal to present minimum criteria [6] |
Water adequacy appraisal: | Better than present minimum criteria [7] |
Roadway alignment appraisal: | Better than present minimum criteria [7] |
Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
Scour condition: | Bridge foundations determined to be stable for assessed or calculated scour conditions; field review indicates action is required. [4] |
Sufficiency rating: | 94.2 |
Estimated cost of work: | $856,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
September 2018 | Fair | Satisfactory | Satisfactory | Satisfactory | 590 | 94.2 |
September 2016 | Fair | Satisfactory | Satisfactory | Satisfactory | 590 | 94.2 |
September 2014 | Fair | Satisfactory | Satisfactory | Satisfactory | 590 | 94.2 |
September 2012 | Fair | Satisfactory | Satisfactory | Satisfactory | 590 | 75.5 |
September 2010 | Fair | Satisfactory | Satisfactory | Satisfactory | 590 | 75.5 |
September 2008 | Fair | Satisfactory | Satisfactory | Satisfactory | 590 | 75.5 |
September 2006 | Fair | Good | Satisfactory | Good | 590 | 76.5 |
August 2004 | Good | Good | Good | Good | 590 | 76.5 |
August 2002 | Good | Good | Good | Good | 590 | 76.5 |
June 2000 | Good | Good | Good | Good | 590 | 76.5 |
June 1998 | Good | Good | Good | Good | 590 | 76.6 |
June 1996 | Good | Good | Good | Good | 590 | 76.5 |
May 1994 | Good | Good | Good | Good | 590 | 76.5 |
September 1992 | Good | Good | Good | Good | 590 | 74.5 |
August 1990 | Good | Good | Good | Good | 590 | 81.5 |