US 231 NBL over WARES FERRY ROAD
Map
Coordinates:
+32.39122, -86.2109632°23'28" N, 86°12'39" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | US 231 NBL over WARES FERRY ROAD |
Structure number: | 008688 |
Old structure number: | 00000009510354B (from 1992 edition) |
Location: | 0.5 MI.N. OF ATLANTA HWY |
Purpose: | Carries highway over highway |
Route classification: | Principal Arterial - Other Freeways or Expressways (Urban) [12] |
Length of largest span: | 55.1 ft. [16.8 m] |
Total length: | 146.0 ft. [44.5 m] |
Roadway width between curbs: | 27.9 ft. [8.5 m] |
Deck width edge-to-edge: | 30.8 ft. [9.4 m] |
Vertical clearance below bridge: | 19.7 ft. [6.0 m] |
Owner: | State Highway Agency [01] |
Year built: | 1965 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18 / HS 20 [5] |
Number of main spans: | 3 |
Main spans material: | Concrete continuous [2] |
Main spans design: | Tee beam [04] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: May 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 18,150 [as of 2013] |
Truck traffic: | 3% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Good [7 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Basically intolerable requiring high priority of replacement [2] |
Underclearances appraisal: | Superior to present desirable criteria [9] |
Roadway alignment appraisal: | Better than present minimum criteria [7] |
Scour condition: | Bridge not over waterway. [N] |
Sufficiency rating: | 78.7 |
Recommended work: | Bridge rehabilitation because of general structure deterioration or inadequate strength. [35] |
Estimated cost of work: | $1,231,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
May 2018 | Fair | Satisfactory | Satisfactory | Good | 18150 | 78.7 |
May 2016 | Fair | Satisfactory | Satisfactory | Good | 18150 | 75.7 |
May 2014 | Fair | Satisfactory | Satisfactory | Good | 18150 | 75.7 |
May 2012 | Fair | Satisfactory | Satisfactory | Good | 20605 | 75.4 |
May 2010 | Fair | Satisfactory | Satisfactory | Good | 18150 | 75.7 |
June 2008 | Fair | Satisfactory | Satisfactory | Good | 18625 | 75.6 |
May 2006 | Fair | Satisfactory | Satisfactory | Good | 19350 | 78.5 |
April 2004 | Fair | Satisfactory | Satisfactory | Good | 19260 | 78.5 |
March 2002 | Fair | Satisfactory | Good | Good | 18370 | 78.6 |
April 2000 | Fair | Satisfactory | Good | Good | 20310 | 76.4 |
April 1998 | Good | Good | Good | Good | 18300 | 76.6 |
April 1996 | Good | Good | Good | Good | 17675 | 76.6 |
March 1994 | Good | Good | Good | Good | 16815 | 76.1 |
February 1992 | Good | Good | Good | Good | 16220 | 76.4 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Reinforced Concrete Girder/Beam | linear ft. | 576 | 576 | 0 | 0 | 0 |
Deck |
Reinforced Concrete Top Flange | sq. ft. | 4,497 | 1 | 2,551 | 1,945 | 0 |
Substructure |
Reinforced Concrete Column | each | 4 | 4 | 0 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 96 | 91 | 5 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 58 | 58 | 0 | 0 | 0 |
Bearings |
Movable Bearing | each | 12 | 0 | 4 | 8 | 0 |
Steel Protective Coating | sq. ft. | 22 | 0 | 0 | 22 | 0 |
Fixed Bearing | each | 4 | 0 | 4 | 0 | 0 |
Steel Protective Coating | sq. ft. | 8 | 0 | 8 | 0 | 0 |
Bridge Rail |
Reinforced Concrete Bridge Rail | linear ft. | 292 | 292 | 0 | 0 | 0 |