Share:

FRANKLIN ST over FAGAN CREEK

Map

Coordinates:
+34.72458, -86.58000
34°43'28" N, 86°34'48" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:FRANKLIN ST over FAGAN CREEK
Structure number:011283
Old structure number:0000016945M0040 (from 1992 edition)
Location:FRANKLIN * LOWE
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Collector (Urban) [17]
Length of largest span:12.1 ft. [3.7 m]
Total length:49.9 ft. [15.2 m]
Roadway width between curbs:40.4 ft. [12.3 m]
Deck width edge-to-edge:54.1 ft. [16.5 m]
Owner:City or Municipal Highway Agency [04]
Year built:1974
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 13.5 / H 15 [2]
Number of main spans:4
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Not applicable [N]

Latest Available Inspection: August 2016

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:7,565 [as of 2015]
Truck traffic:1% of total traffic
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Better than present minimum criteria [7]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Culvert condition:Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:70.0 tons [63.6 metric tons]
Inventory rating:41.9 tons [38.1 metric tons]
Sufficiency rating:79.1
Estimated cost of work:$1,063,000

Previous Inspections

DateSuff. RatingConditionCulvert ConditionSD/FOADT
August 201679.1Good7 out of 10-7565
August 201479.1Good7 out of 10-7565
August 201279.1Good7 out of 10-7565
August 201079.1Good7 out of 10-7565
August 200857.2Good7 out of 10-7565
October 200657.2Good7 out of 10-7565
October 200457.2Good7 out of 10-7565
October 200257.2Good7 out of 10-7565
November 200057.2Good7 out of 10-7565
November 199857.4Good7 out of 10-7560
December 199657.2Good7 out of 10-7550
December 199457.5Good7 out of 10-7500
January 199357.5Good7 out of 10-7400
December 199064.7Good7 out of 10-7300