Share:

CO RD 29 over WHITE CREEK

Map

Coordinates:
+32.82167, -87.88667
32°49'18" N, 87°53'12" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:CO RD 29 over WHITE CREEK
Structure number:012169
Old structure number:0000002932030Z0 (from 1992 edition)
Location:0.4 MI N US HWY 43
Purpose:Carries highway over waterway
Route classification:Minor Collector (Rural) [08]
Length of largest span:9.8 ft. [3.0 m]
Total length:44.0 ft. [13.4 m]
Roadway width between curbs:58.1 ft. [17.7 m]
Deck width edge-to-edge:62.3 ft. [19.0 m]
Skew angle:45°
Owner:City or Municipal Highway Agency [04]
Year built:1979
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:4
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Not applicable [N]

Latest Available Inspection: March 2018

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:2,040 [as of 1995]
Truck traffic:95% of total traffic
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Superior to present desirable criteria [9]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Better than present minimum criteria [7]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Culvert condition:Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:96.5
Estimated cost of work:$794,000

Previous Inspections

DateConditionCulvert ConditionADTSuff. Rating
March 2018Fair6 out of 10204096.5
March 2016Fair6 out of 10204096.5
March 2014Fair6 out of 10204096.5
March 2012Fair6 out of 10204096.5
March 2010Fair6 out of 10204096.5
February 2008Fair6 out of 10204096.5
March 2007Fair6 out of 10204096.5
January 2003Fair6 out of 10204096.5
February 2001Fair6 out of 10204096.5
February 1999Fair6 out of 10204096.4
December 1996Fair6 out of 10204096.4
January 1995Fair6 out of 10204099.4
February 1993Fair6 out of 10195096.4
January 1991Fair6 out of 10195077.5