Share:

CO RT 215 over WHITEWATER BRANCH

Map

Coordinates:
+31.53769, -85.99491
31°32'16" N, 85°59'42" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:CO RT 215 over WHITEWATER BRANCH
Structure number:015928
Location:9.4 MI. N. OF RICHBURG
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:5.9 ft. [1.8 m]
Total length:25.9 ft. [7.9 m]
Owner:County Highway Agency [02]
Year built:1982
Year reconstructed:2000
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 13.5 / H 15 [2]
Number of main spans:4
Main spans material:Steel [3]
Main spans design:Culvert [19]
Deck type:Not applicable [N]

Latest Available Inspection: September 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:254 [as of 2016]
Truck traffic:5% of total traffic
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Better than present minimum criteria [7]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Culvert condition:Moderate to major deterioration or disintegration, extensive cracking and leaching or spalls on concrete or masonry walls and slabs. Minor settlement or misalignment. Noticeable scouring or erosion at curtain walls, wingwalls or pipes. Metal culverts have significant distortion and deflection in one section, significant corrosion or deep pitting. [5]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:88.9
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$276,000

Previous Inspections

DateConditionCulvert ConditionADTSuff. Rating
September 2016Fair5 out of 1025488.9
August 2014Fair6 out of 1025479.6
August 2012Good7 out of 1025465.4
September 2010Good7 out of 1025465.4
September 2008Good7 out of 1025465.4
October 2006Good7 out of 1025465.4
October 2004Good7 out of 1025465.4
October 2002Good7 out of 1025465.4
December 2000Good7 out of 1025465.4
February 2000Good7 out of 1025465.3
January 1999Poor4 out of 1025442.6
November 1996Poor4 out of 1025442.6
January 1995Poor4 out of 1025442.6