Share:

SR 255 over STREAM

Map

Coordinates:
+34.76627, -86.67277
34°45'59" N, 86°40'22" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts

Name:SR 255 over STREAM
Structure number:016515
Location:1.4MILES N JCT US 72
Purpose:Carries highway over waterway
Route classification:Principal Arterial - Other Freeways or Expressways (Urban) [12]
Length of largest span:9.8 ft. [3.0 m]
Total length:21.0 ft. [6.4 m]
Owner:State Highway Agency [01]
Year built:1992
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:2
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Not applicable [N]
Wearing surface:Bituminous [6]

Latest Available Inspection: October 2015

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:29,214 [as of 2015]
Truck traffic:8% of total traffic
Structural appraisal:Better than present minimum criteria [7]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Culvert condition:Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:97.8 tons [88.9 metric tons]
Inventory rating:75.1 tons [68.3 metric tons]
Sufficiency rating:81.7
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$1,673,000

Previous Inspections

DateSuff. RatingConditionCulvert ConditionSD/FOADT
October 201581.7Good7 out of 10-29214
October 201381.8Good7 out of 10-28090
October 201181.9Good8 out of 10-27206
October 200982.0Good8 out of 10-26800
October 200780.6Good8 out of 10-38760
October 200578.2Good8 out of 10FO23410
October 200376.6Good8 out of 10FO36150
October 200176.6Good8 out of 10FO36150
October 199977.2Good8 out of 10-14820
November 199780.4Good8 out of 10-22560
November 199580.4Good8 out of 10-22560