SH 16/Cleburne Co over CADRON CREEK
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | SH 16/Cleburne Co over CADRON CREEK |
Structure number: | 000000000003331 |
Location: | 1.30 MI NW JCT SH16-25 |
Purpose: | Carries highway over waterway |
Route classification: | Major Collector (Rural) [07] |
Length of largest span: | 19.0 ft. [5.8 m] |
Total length: | 132.9 ft. [40.5 m] |
Roadway width between curbs: | 24.0 ft. [7.3 m] |
Deck width edge-to-edge: | 26.2 ft. [8.0 m] |
Owner: | State Highway Agency [01] |
Year built: | 1961 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | M 13.5 / H 15 [2] |
Number of main spans: | 7 |
Main spans material: | Concrete [1] |
Main spans design: | Channel beam [22] |
Deck type: | Concrete Precast Panels [2] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: April 2018
Good/Fair/Poor Condition: | Good |
Status: | Open, no restriction [A] |
Average daily traffic: | 2,500 [as of 2014] |
Truck traffic: | 1% of total traffic |
Deck condition: | Good [7 out of 9] |
Superstructure condition: | Good [7 out of 9] |
Substructure condition: | Good [7 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Basically intolerable requiring high priority of replacement [2] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Better than present minimum criteria [7] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Pier/abutment protection: | Navigation protection not required [1] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 61.8 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
April 2018 | Good | Good | Good | Good | 2500 | 61.8 |
April 2016 | Good | Good | Good | Good | 2300 | 76.2 |
April 2014 | Good | Good | Good | Good | 2300 | 76.2 |
April 2012 | Good | Good | Good | Good | 2300 | 76.2 |
May 2010 | Good | Good | Good | Good | 2300 | 76.2 |
May 2008 | Good | Good | Good | Good | 2300 | 54.1 |
June 2006 | Good | Good | Good | Good | 2100 | 54.3 |
May 2004 | Good | Good | Good | Good | 2300 | 54.1 |
April 2002 | Good | Very Good | Good | Very Good | 1900 | 56.4 |
May 2000 | Good | Very Good | Good | Very Good | 1800 | 56.5 |
April 1998 | Good | Very Good | Good | Very Good | 1800 | 56.5 |
April 1996 | Fair | Good | Satisfactory | Good | 725 | 63.8 |
April 1994 | Fair | Good | Satisfactory | Good | 725 | 63.1 |
April 1992 | Fair | Good | Satisfactory | Good | 725 | 63.1 |
April 1990 | Fair | Good | Satisfactory | Very Good | 855 | 57.8 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Reinforced Concrete Girder/Beam | linear ft. | 931 | 877 | 36 | 18 | 0 |
Deck |
Reinforced Concrete Top Flange | sq. ft. | 3,485 | 3,353 | 132 | 0 | 0 |
Wearing Surfaces | sq. ft. | 3,205 | 2,871 | 190 | 144 | 0 |
Substructure |
Reinforced Concrete Column | each | 12 | 5 | 6 | 1 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 212 | 197 | 6 | 9 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 266 | 165 | 101 | 0 | 0 |
Steel Protective Coating | sq. ft. | 798 | 498 | 0 | 0 | 300 |