SH 28-Scott Co. over Kelly Creek
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | SH 28-Scott Co. over Kelly Creek |
Structure number: | 000000000003340 |
Location: | 1.5 MI W OF NOLA |
Purpose: | Carries highway over waterway |
Route classification: | Major Collector (Rural) [07] |
Length of largest span: | 27.9 ft. [8.5 m] |
Total length: | 84.0 ft. [25.6 m] |
Roadway width between curbs: | 24.0 ft. [7.3 m] |
Deck width edge-to-edge: | 26.6 ft. [8.1 m] |
Owner: | State Highway Agency [01] |
Year built: | 1961 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | M 13.5 / H 15 [2] |
Number of main spans: | 3 |
Main spans material: | Concrete [1] |
Main spans design: | Slab [01] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: December 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 280 [as of 2014] |
Truck traffic: | 1% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Equal to present minimum criteria [6] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Pier/abutment protection: | Navigation protection not required [1] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 81.7 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
December 2017 | Fair | Satisfactory | Satisfactory | Satisfactory | 280 | 81.7 |
December 2015 | Fair | Satisfactory | Satisfactory | Satisfactory | 270 | 81.8 |
December 2013 | Fair | Good | Good | Satisfactory | 270 | 81.8 |
February 2012 | Fair | Good | Good | Satisfactory | 300 | 66.2 |
January 2010 | Fair | Good | Good | Satisfactory | 300 | 66.2 |
February 2008 | Fair | Good | Good | Satisfactory | 250 | 70.8 |
March 2006 | Good | Good | Very Good | Good | 250 | 70.8 |
April 2004 | Good | Good | Very Good | Good | 240 | 70.9 |
April 2002 | Good | Good | Very Good | Very Good | 280 | 66.1 |
April 2000 | Good | Good | Very Good | Very Good | 300 | 66.0 |
April 1998 | Good | Good | Very Good | Very Good | 300 | 66.0 |
April 1996 | Fair | Satisfactory | Satisfactory | Good | 150 | 70.8 |
April 1994 | Fair | Satisfactory | Satisfactory | Good | 150 | 70.3 |
April 1992 | Fair | Satisfactory | Satisfactory | Good | 150 | 70.3 |
April 1990 | Fair | Satisfactory | Good | Very Good | 341 | 65.0 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Substructure |
Reinforced Concrete Column | each | 4 | 2 | 2 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 60 | 60 | 0 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 50 | 39 | 7 | 4 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 168 | 134 | 34 | 0 | 0 |
Deck |
Reinforced Concrete Slab | sq. ft. | 2,016 | 1,386 | 588 | 42 | 0 |