SH 74 Searcy Co. over CALF CREEK
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | SH 74 Searcy Co. over CALF CREEK |
Structure number: | 000000000003972 |
Location: | 7 MI W OF JCT US 65 |
Purpose: | Carries highway over waterway |
Route classification: | Major Collector (Rural) [07] |
Length of largest span: | 29.9 ft. [9.1 m] |
Total length: | 180.1 ft. [54.9 m] |
Roadway width between curbs: | 25.9 ft. [7.9 m] |
Deck width edge-to-edge: | 28.9 ft. [8.8 m] |
Owner: | State Highway Agency [01] |
Year built: | 1975 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | M 18 / H 20 [4] |
Number of main spans: | 6 |
Main spans material: | Concrete [1] |
Main spans design: | Slab [01] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: November 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 780 [as of 2014] |
Truck traffic: | 1% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Water adequacy appraisal: | Equal to present minimum criteria [6] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
Pier/abutment protection: | Navigation protection not required [1] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 83.7 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
November 2018 | Fair | Satisfactory | Satisfactory | Satisfactory | 780 | 83.7 |
November 2016 | Fair | Fair | Fair | Satisfactory | 740 | 77.9 |
November 2014 | Fair | Fair | Fair | Satisfactory | 740 | 77.9 |
November 2012 | Fair | Fair | Fair | Satisfactory | 830 | 70.4 |
November 2010 | Fair | Fair | Fair | Satisfactory | 830 | 70.4 |
November 2008 | Fair | Fair | Fair | Satisfactory | 830 | 60.6 |
November 2006 | Fair | Fair | Fair | Satisfactory | 740 | 68.3 |
November 2004 | Fair | Fair | Fair | Satisfactory | 740 | 68.3 |
November 2002 | Fair | Fair | Fair | Satisfactory | 710 | 68.1 |
December 2000 | Fair | Satisfactory | Satisfactory | Satisfactory | 730 | 80.5 |
December 1998 | Fair | Satisfactory | Satisfactory | Satisfactory | 730 | 80.5 |
December 1996 | Fair | Very Good | Very Good | Satisfactory | 325 | 83.0 |
November 1994 | Fair | Very Good | Very Good | Satisfactory | 325 | 82.5 |
November 1992 | Fair | Very Good | Very Good | Satisfactory | 325 | 82.5 |
October 1990 | Fair | Very Good | Very Good | Satisfactory | 401 | 89.6 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Substructure |
Reinforced Concrete Column | each | 10 | 2 | 5 | 3 | 0 |
Reinforced Concrete Abutment | linear ft. | 70 | 66 | 3 | 1 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 146 | 98 | 9 | 39 | 0 |
Bridge Rail |
Reinforced Concrete Bridge Rail | linear ft. | 360 | 335 | 0 | 25 | 0 |
Deck |
Reinforced Concrete Slab | sq. ft. | 5,184 | 4,747 | 400 | 37 | 0 |