SH 74 Searcy over BEAR CREEK
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | SH 74 Searcy over BEAR CREEK |
Structure number: | 000000000003973 |
Location: | 0.01MI W JCT US 65 & 74 |
Purpose: | Carries highway over waterway |
Route classification: | Major Collector (Rural) [07] |
Length of largest span: | 47.9 ft. [14.6 m] |
Total length: | 290.0 ft. [88.4 m] |
Roadway width between curbs: | 25.9 ft. [7.9 m] |
Deck width edge-to-edge: | 28.2 ft. [8.6 m] |
Owner: | State Highway Agency [01] |
Year built: | 1975 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | M 18 / H 20 [4] |
Number of main spans: | 6 |
Main spans material: | Steel [3] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: November 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 780 [as of 2014] |
Truck traffic: | 1% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Fair [5 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
Pier/abutment protection: | Navigation protection not required [1] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 72.4 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
November 2018 | Fair | Satisfactory | Fair | Satisfactory | 780 | 72.4 |
November 2016 | Poor | Satisfactory | Poor | Satisfactory | 740 | 62.8 |
October 2014 | Good | Good | Good | Good | 740 | 91.0 |
November 2012 | Good | Good | Good | Good | 830 | 83.7 |
November 2010 | Good | Good | Good | Good | 830 | 83.7 |
November 2008 | Good | Good | Good | Good | 830 | 73.4 |
November 2006 | Good | Good | Good | Good | 740 | 80.8 |
November 2004 | Good | Good | Good | Good | 740 | 80.8 |
November 2002 | Good | Good | Good | Good | 710 | 80.6 |
December 2000 | Good | Good | Good | Good | 730 | 80.5 |
December 1998 | Good | Good | Very Good | Good | 730 | 80.5 |
December 1996 | Good | Good | Very Good | Good | 325 | 83.0 |
November 1994 | Good | Good | Very Good | Very Good | 325 | 82.5 |
November 1992 | Good | Good | Very Good | Very Good | 325 | 82.5 |
October 1990 | Good | Good | Very Good | Very Good | 401 | 89.6 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 1,152 | 1,019 | 81 | 51 | 1 |
Deck |
Reinforced Concrete Deck | sq. ft. | 7,488 | 6,309 | 1,080 | 99 | 0 |
Substructure |
Reinforced Concrete Column | each | 5 | 1 | 4 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 66 | 61 | 5 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 125 | 47 | 0 | 78 | 0 |
Bearings |
Movable Bearing | each | 24 | 0 | 3 | 21 | 0 |
Fixed Bearing | each | 24 | 3 | 1 | 20 | 0 |
Bridge Rail |