SH 109 over ARKANSAS RIVER
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | SH 109 over ARKANSAS RIVER |
Structure number: | 000000000005600 |
Location: | 1.5 MI SO JCT 194 |
Purpose: | Carries highway over waterway |
Route classification: | Minor Arterial (Rural) [06] |
Length of largest span: | 410.1 ft. [125.0 m] |
Total length: | 8537.5 ft. [2602.1 m] |
Roadway width between curbs: | 29.9 ft. [9.1 m] |
Deck width edge-to-edge: | 32.8 ft. [10.0 m] |
Vertical clearance below bridge: | 49.2 ft. [15.0 m] |
Owner: | State Highway Agency [01] |
Year built: | 1980 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18 / HS 20 [5] |
Number of main spans: | 3 |
Main spans material: | Steel continuous [4] |
Main spans design: | Girder and floorbeam system [03] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: April 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 3,900 [as of 2014] |
Truck traffic: | 1% of total traffic |
Deck condition: | Good [7 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Good [7 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Pier/abutment protection: | None present but re-evaluation suggested [5] |
Scour condition: | Bridge foundations determined to be stable for assessed or calculated scour condition. [5] |
Sufficiency rating: | 68.2 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
April 2018 | Fair | Good | Satisfactory | Good | 3900 | 68.2 |
April 2016 | Fair | Good | Satisfactory | Good | 3800 | 68.6 |
May 2014 | Fair | Good | Satisfactory | Good | 3800 | 68.6 |
April 2012 | Fair | Good | Satisfactory | Good | 3800 | 68.6 |
March 2010 | Fair | Good | Satisfactory | Good | 3800 | 68.6 |
March 2008 | Fair | Good | Satisfactory | Good | 3800 | 68.6 |
April 2006 | Fair | Good | Satisfactory | Good | 4800 | 67.9 |
February 2004 | Fair | Good | Satisfactory | Good | 4600 | 67.9 |
January 2002 | Fair | Good | Satisfactory | Good | 4300 | 67.9 |
October 1999 | Good | Good | Good | Good | 4300 | 67.9 |
August 1997 | Good | Good | Good | Good | 3500 | 69.7 |
March 1995 | Good | Good | Good | Good | 1885 | 83.7 |
April 1993 | Good | Good | Good | Good | 1885 | 83.7 |
November 1990 | Good | Very Good | Very Good | Very Good | 1642 | 84.6 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 31,640 | 26,728 | 4,891 | 1 | 20 |
Steel Stringer | linear ft. | 1,860 | 1,439 | 421 | 0 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 278,804 | 211,632 | 67,172 | 0 | 0 |
Superstructure |
Steel Floor Beam | linear ft. | 990 | 890 | 100 | 0 | 0 |
Substructure |
Reinforced Concrete Pier Wall | linear ft. | 573 | 569 | 0 | 4 | 0 |
Reinforced Concrete Abutment | linear ft. | 104 | 98 | 0 | 6 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 1,580 | 1,349 | 226 | 5 | 0 |
Bearings |
Movable Bearing | each | 188 | 181 | 4 | 3 | 0 |
Fixed Bearing | each | 96 | 89 | 7 | 0 | 0 |
Bridge Rail |
Reinforced Concrete Bridge Rail | linear ft. | 17,074 | 11,130 | 5,882 | 62 | 0 |