SH 19 S1 L 0.06 over Cypress Creek
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | SH 19 S1 L 0.06 over Cypress Creek |
Structure number: | 000000000006799 |
Location: | .06 MI N. LA. St Line |
Purpose: | Carries highway over waterway |
Route classification: | Major Collector (Rural) [07] |
Length of largest span: | 40.0 ft. [12.2 m] |
Total length: | 190.0 ft. [57.9 m] |
Roadway width between curbs: | 29.9 ft. [9.1 m] |
Deck width edge-to-edge: | 32.8 ft. [10.0 m] |
Owner: | State Highway Agency [01] |
Year built: | 2001 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18 / HS 20 [5] |
Number of main spans: | 5 |
Main spans material: | Steel continuous [4] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: April 2017
Good/Fair/Poor Condition: | Good |
Status: | Open, no restriction [A] |
Average daily traffic: | 560 [as of 2014] |
Truck traffic: | 1% of total traffic |
Deck condition: | Good [7 out of 9] |
Superstructure condition: | Very Good [8 out of 9] |
Substructure condition: | Very Good [8 out of 9] |
Structural appraisal: | Equal to present desirable criteria [8] |
Deck geometry appraisal: | Equal to present minimum criteria [6] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8] |
Pier/abutment protection: | Navigation protection not required [1] |
Scour condition: | Bridge foundations determined to be stable for assessed or calculated scour condition. [5] |
Sufficiency rating: | 99.2 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
April 2017 | Good | Good | Very Good | Very Good | 560 | 99.2 |
April 2015 | Good | Very Good | Very Good | Very Good | 600 | 99.1 |
April 2013 | Good | Very Good | Very Good | Very Good | 600 | 99.1 |
April 2011 | Good | Very Good | Very Good | Very Good | 610 | 99.1 |
April 2009 | Good | Very Good | Very Good | Very Good | 610 | 99.1 |
April 2007 | Good | Very Good | Very Good | Very Good | 540 | 99.2 |
April 2005 | Good | Very Good | Very Good | Very Good | 530 | 99.2 |
June 2003 | Good | Very Good | Very Good | Very Good | 590 | 99.1 |
June 2001 | Good | Excellent | Excellent | Excellent | 700 | 98.9 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 752 | 752 | 0 | 0 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 6,372 | 4,868 | 1,504 | 0 | 0 |
Substructure |
Reinforced Concrete Abutment | linear ft. | 102 | 102 | 0 | 0 | 0 |
Reinforced Concrete Pile | each | 16 | 16 | 0 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 130 | 130 | 0 | 0 | 0 |
Bearings |
Elastomeric Bearing | each | 24 | 24 | 0 | 0 | 0 |
Bridge Rail |
Reinforced Concrete Bridge Rail | linear ft. | 380 | 342 | 38 | 0 | 0 |