CO RD 18-F over Choctaw Creek
This bridge is no longer in the current National Bridge Inventory database, and has likely been demolished or abandoned.
Map
Coordinates:
+35.50806, -92.4713935°30'29" N, 92°28'17" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | CO RD 18-F over Choctaw Creek |
Structure number: | 000000000021006 |
Location: | .1 MILE EAST JCT SH 9 |
Purpose: | Carries highway over waterway |
Route classification: | Local (Rural) [09] |
Length of largest span: | 34.8 ft. [10.6 m] |
Total length: | 62.0 ft. [18.9 m] |
Roadway width between curbs: | 9.8 ft. [3.0 m] |
Deck width edge-to-edge: | 9.8 ft. [3.0 m] |
Owner: | County Highway Agency [02] |
Year built: | 1991 |
Historic significance: | Historical significance is not determinable at this time [4] |
Number of main spans: | 3 |
Main spans material: | Steel [3] |
Main spans design: | Orthotropic [08] |
Deck type: | Steel plate (includes orthotropic) [5] |
Wearing surface: | Other [9] |
Latest Available Inspection: July 2011
Good/Fair/Poor Condition: | Fair |
Status: | Posted for load [P] |
Average daily traffic: | 41 [as of 1987] |
Truck traffic: | 1% of total traffic |
Deck condition: | Fair [5 out of 9] |
Superstructure condition: | Fair [5 out of 9] |
Substructure condition: | Fair [5 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Basically intolerable requiring high priority of replacement [2] |
Water adequacy appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Roadway alignment appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Pier/abutment protection: | Navigation protection not required [1] |
Scour condition: | Bridge foundations determined to be stable for assessed or calculated scour condition. [5] |
Sufficiency rating: | 58.0 |
Recommended work: | Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31] |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
July 2011 | Fair | Fair | Fair | Fair | 41 | 58.0 |
July 2009 | Fair | Fair | Fair | Fair | 41 | 64.0 |
August 2007 | Fair | Fair | Satisfactory | Satisfactory | 41 | 75.0 |
July 2005 | Fair | Fair | Satisfactory | Satisfactory | 41 | 75.0 |
July 2003 | Fair | Satisfactory | Good | Satisfactory | 41 | 76.0 |
July 2001 | Good | Very Good | Very Good | Good | 41 | 76.0 |
August 1999 | Good | Very Good | Very Good | Very Good | 41 | 76.0 |
July 1997 | Good | Very Good | Very Good | Very Good | 41 | 76.0 |
September 1995 | Good | Very Good | Very Good | Very Good | 41 | 76.0 |
September 1993 | Good | Very Good | Very Good | Very Good | 41 | 76.0 |
July 1991 | Good | Very Good | Very Good | Very Good | 41 | 76.0 |