SH 337/Cleburne Co over DITCH
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | SH 337/Cleburne Co over DITCH |
Structure number: | 0000000000M3769 |
Location: | 0.3 MI SE JCT SH 337-25 |
Purpose: | Carries highway over waterway |
Route classification: | Major Collector (Rural) [07] |
Length of largest span: | 12.1 ft. [3.7 m] |
Total length: | 34.8 ft. [10.6 m] |
Roadway width between curbs: | 36.1 ft. [11.0 m] |
Deck width edge-to-edge: | 36.4 ft. [11.1 m] |
Owner: | State Highway Agency [01] |
Year built: | 1938 |
Year reconstructed: | 1994 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | M 13.5 / H 15 [2] |
Number of main spans: | 3 |
Main spans material: | Concrete [1] |
Main spans design: | Culvert [19] |
Deck type: | Not applicable [N] |
Latest Available Inspection: April 2017
Good/Fair/Poor Condition: | Good |
Status: | Open, no restriction [A] |
Average daily traffic: | 2,000 [as of 2014] |
Truck traffic: | 1% of total traffic |
Structural appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Deck geometry appraisal: | Equal to present minimum criteria [6] |
Water adequacy appraisal: | Equal to present minimum criteria [6] |
Roadway alignment appraisal: | Better than present minimum criteria [7] |
Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
Pier/abutment protection: | Navigation protection not required [1] |
Culvert condition: | Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7] |
Scour condition: | Bridge foundations determined to be stable for assessed or calculated scour condition. [5] |
Sufficiency rating: | 70.7 |
Previous Inspections
Date | Condition | Culvert Condition | ADT | Suff. Rating |
---|
April 2017 | Good | 7 out of 10 | 2000 | 70.7 |
April 2015 | Good | 7 out of 10 | 1800 | 71.2 |
April 2013 | Good | 7 out of 10 | 1800 | 71.2 |
May 2012 | Good | 7 out of 10 | 1800 | 71.2 |
May 2010 | Good | 7 out of 10 | 1800 | 71.2 |
April 2008 | Good | N out of 10 | 1800 | 90.6 |
June 2006 | Good | N out of 10 | 1700 | 90.8 |
May 2004 | Good | N out of 10 | 1700 | 90.8 |
April 2002 | Good | N out of 10 | 2000 | 90.0 |
April 2000 | Good | N out of 10 | 4300 | 84.4 |
April 1998 | Fair | N out of 10 | 4300 | 84.4 |
April 1996 | Good | N out of 10 | 740 | 92.4 |
May 1994 | Good | N out of 10 | 740 | 73.7 |
May 1992 | Good | N out of 10 | 740 | 62.5 |
April 1990 | Good | N out of 10 | 198 | 71.2 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Culvert |
Reinforced Concrete Culvert | linear ft. | 31 | 0 | 31 | 0 | 0 |
Masonry Culvert | linear ft. | 81 | 0 | 0 | 81 | 0 |