Share:

IRR BIA RTE 3 over SANDY WASH

Map

Coordinates:
+33.21853, -110.50711
33°13'07" N, 110°30'26" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:IRR BIA RTE 3 over SANDY WASH
Structure number:00000000000H209
Location:12.4 KM S OF AZ 70/170JCT
Purpose:Carries highway over waterway
Route classification:Minor Arterial (Rural) [06]
Length of largest span:10.8 ft. [3.3 m]
Total length:44.3 ft. [13.5 m]
Roadway width between curbs:26.9 ft. [8.2 m]
Deck width edge-to-edge:46.3 ft. [14.1 m]
Owner:Bureau of Indian Affairs [62]
Year built:1987
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:4
Main spans material:Concrete continuous [2]
Main spans design:Culvert [19]
Deck type:Not applicable [N]

Latest Available Inspection: November 2016

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:514 [as of 2016]
Truck traffic:4% of total traffic
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Culvert condition:Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:89.2

Previous Inspections

DateConditionCulvert ConditionADTSuff. Rating
November 2016Good7 out of 1051489.2
October 2014Fair6 out of 1051489.2
January 2012Fair6 out of 1051489.2
December 2009Good7 out of 1051489.2
June 2008Good7 out of 1051489.2
March 2003Good7 out of 1051493.3
November 2001Good7 out of 1051493.3
November 1997Good7 out of 1051496.3
August 1995Good7 out of 1051493.4
November 1993Good8 out of 1032097.0