US 60 over Queen Creek
Map
Coordinates:
+33.29820, -111.0895033°17'54" N, 111°05'22" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | US 60 over Queen Creek |
Structure number: | 00406 |
Location: | 0.5 mi E Jct SR 177 |
Purpose: | Carries highway over waterway |
Route classification: | Principal Arterial - Other (Rural) [02] |
Length of largest span: | 380.9 ft. [116.1 m] |
Total length: | 577.1 ft. [175.9 m] |
Roadway width between curbs: | 29.9 ft. [9.1 m] |
Deck width edge-to-edge: | 34.1 ft. [10.4 m] |
Owner: | State Highway Agency [01] |
Year built: | 1949 |
Historic significance: | Bridge is possibly eligible for the National Register of Historic Places [3] |
Design load: | MS 18 / HS 20 [5] |
Main span material: | Steel [3] |
Main span design: | Arch - Deck [11] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: September 2018
Good/Fair/Poor Condition: | Poor |
Status: | Open, no restriction [A] |
Average daily traffic: | 7,925 [as of 2017] |
Truck traffic: | 10% of total traffic |
Deck condition: | Poor [4 out of 9] |
Superstructure condition: | Poor [4 out of 9] |
Substructure condition: | Poor [4 out of 9] |
Structural appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Deck geometry appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Channel protection: | Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 36.3 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
September 2018 | Poor | Poor | Poor | Poor | 7925 | 36.3 |
September 2016 | Poor | Poor | Serious | Poor | 7612 | 19.3 |
September 2014 | Poor | Poor | Poor | Poor | 7335 | 36.2 |
September 2012 | Poor | Poor | Poor | Poor | 11000 | 36.2 |
October 2010 | Poor | Poor | Poor | Poor | 8467 | 36.2 |
January 2010 | Poor | Fair | Fair | Poor | 8467 | 38.2 |
December 2007 | Poor | Fair | Fair | Poor | 6800 | 39.0 |
June 2006 | Poor | Fair | Satisfactory | Poor | 6500 | 39.0 |
August 2004 | Fair | Satisfactory | Satisfactory | Satisfactory | 6249 | 66.9 |
October 2001 | Fair | Satisfactory | Satisfactory | Satisfactory | 6795 | 66.9 |
March 2000 | Fair | Satisfactory | Good | Satisfactory | 7044 | 67.9 |
November 1997 | Fair | Satisfactory | Good | Satisfactory | 6938 | 67.9 |
February 1996 | Fair | Satisfactory | Good | Satisfactory | 5780 | 67.9 |
March 1993 | Fair | Satisfactory | Good | Satisfactory | 5100 | 67.9 |
March 1992 | Good | Good | Good | Good | 5100 | 67.9 |
May 1991 | Good | Good | Very Good | Very Good | 6000 | 67.9 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 751 | 0 | 641 | 110 | 0 |
Steel Protective Coating | sq. ft. | 6,819 | 6,819 | 0 | 0 | 0 |
Steel Stringer | linear ft. | 1,483 | 0 | 1,342 | 141 | 0 |
Steel Protective Coating | sq. ft. | 9,091 | 0 | 9,091 | 0 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 19,618 | 2,308 | 16,910 | 400 | 0 |
Wearing Surfaces | sq. ft. | 17,310 | 0 | 16,910 | 400 | 0 |
Superstructure |
Steel Arch | linear ft. | 699 | 0 | 510 | 150 | 39 |
Steel Protective Coating | sq. ft. | 15,448 | 0 | 11,271 | 0 | 4,177 |
Steel Floor Beam | linear ft. | 420 | 0 | 396 | 20 | 4 |
Steel Protective Coating | sq. ft. | 3,788 | 0 | 3,788 | 0 | 0 |
Steel Pin or Pin & Hangar Assembly | each | 4 | 0 | 4 | 0 | 0 |
Substructure |
Steel Column | each | 24 | 8 | 0 | 16 | 0 |
Steel Protective Coating | sq. ft. | 6,896 | 0 | 6,896 | 0 | 0 |
Reinforced Concrete Column | each | 8 | 0 | 4 | 4 | 0 |
Reinforced Concrete Abutment | linear ft. | 72 | 0 | 42 | 30 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 157 | 0 | 120 | 37 | 0 |
Joints |
Compression Joint | linear ft. | 180 | 105 | 15 | 0 | 60 |
Bearings |
Movable Bearing | each | 12 | 0 | 10 | 2 | 0 |
Fixed Bearing | each | 20 | 0 | 20 | 0 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 1,154 | 1,016 | 38 | 100 | 0 |