Share:

I 10; EB & WB over Wash

Map

Coordinates:
+32.33333, -109.52833
32°19'60" N, 109°31'42" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:I 10; EB & WB over Wash
Structure number:05646
Location:5.9 mi East Jct SR 191
Purpose:Carries highway over waterway
Route classification:Principal Arterial - Interstate (Rural) [01]
Length of largest span:9.8 ft. [3.0 m]
Total length:32.2 ft. [9.8 m]
Owner:State Highway Agency [01]
Year built:1967
Year reconstructed:1993
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:3
Main spans material:Concrete continuous [2]
Main spans design:Culvert [19]
Deck type:Not applicable [N]

Latest Available Inspection: September 2016

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:12,207 [as of 2014]
Truck traffic:37% of total traffic
Structural appraisal:Better than present minimum criteria [7]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Culvert condition:Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:71.8 tons [65.3 metric tons]
Inventory rating:41.9 tons [38.1 metric tons]
Sufficiency rating:69.7
Recommended work:Widening of existing bridge or other major structure without deck rehabilitation or replacement [33]
Estimated cost of work:$1,000

Previous Inspections

DateSuff. RatingConditionCulvert ConditionSD/FOADT
September 201669.7Good7 out of 10-12207
September 201265.0Good7 out of 10-13000
October 200880.0Good8 out of 10-14100
September 200497.1Good8 out of 10-18810
January 200097.3Good8 out of 10-14234
December 199597.3Good8 out of 10-9570
April 199297.7Good8 out of 10-4600
April 199097.4Good8 out of 10-8200