INTERSTATE 5 over SACRAMENTO RIVER
This bridge is no longer in the current National Bridge Inventory database, and has likely been demolished or abandoned.
Map
Coordinates:
+40.88167, -122.3800040°52'54" N, 122°22'48" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | INTERSTATE 5 over SACRAMENTO RIVER |
Structure number: | 06 0089 |
Location: | 02-SHA-005-R40.16 |
Purpose: | Carries highway over waterway |
Route classification: | Principal Arterial - Interstate (Rural) [01] |
Length of largest span: | 273.0 ft. [83.2 m] |
Total length: | 1330.1 ft. [405.4 m] |
Roadway width between curbs: | 54.1 ft. [16.5 m] |
Deck width edge-to-edge: | 59.7 ft. [18.2 m] |
Vertical clearance below bridge: | 17.4 ft. [5.3 m] |
Skew angle: | 99° |
Owner: | State Highway Agency [01] |
Year built: | 1941 |
Year reconstructed: | 1967 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 13.5 / HS 15 [3] |
Number of main spans: | 7 |
Main spans material: | Steel continuous [4] |
Main spans design: | Truss - Deck [09] |
Deck type: | Concrete Cast-in-Place [1] |
Latest Available Inspection: May 2014
Good/Fair/Poor Condition: | Poor |
Status: | Open, no restriction [A] |
Average daily traffic: | 17,200 [as of 2009] |
Truck traffic: | 30% of total traffic |
Deck condition: | Serious [3 out of 9] |
Superstructure condition: | Fair [5 out of 9] |
Substructure condition: | Good [7 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Better than present minimum criteria [7] |
Channel protection: | Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8] |
Scour condition: | Bridge foundations determined to be stable for assessed or calculated scour condition. [5] |
Sufficiency rating: | 47.0 |
Recommended work: | Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31] |
Estimated cost of work: | $12,870,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
May 2014 | Poor | Serious | Fair | Good | 17200 | 47.0 |
May 2012 | Poor | Serious | Fair | Good | 17200 | 50.0 |
May 2010 | Poor | Serious | Fair | Good | 18400 | 50.0 |
May 2008 | Poor | Serious | Fair | Good | 18400 | 50.0 |
May 2007 | Poor | Serious | Fair | Good | 17900 | 50.0 |
December 2006 | Poor | Serious | Fair | Good | 17900 | 50.0 |
May 2003 | Poor | Poor | Poor | Good | 15500 | 36.0 |
April 2003 | Fair | Satisfactory | Fair | Good | 15500 | 50.0 |
October 2001 | Poor | Satisfactory | Poor | Good | 15500 | 39.0 |
November 2000 | Fair | Satisfactory | Satisfactory | Good | 15500 | 61.0 |
February 2000 | Fair | Good | Satisfactory | Good | 15500 | 61.0 |
July 1998 | Fair | Good | Satisfactory | Good | 15500 | 61.0 |
August 1994 | Poor | Fair | Poor | Good | 17300 | 37.8 |
May 1990 | Poor | Fair | Poor | Good | 16000 | 37.8 |