Share:

FLORIN RD (SACTO) over ANDERSON DRAIN

Map

Coordinates:
+38.49569, -121.47751
38°29'44" N, 121°28'39" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:FLORIN RD (SACTO) over ANDERSON DRAIN
Structure number:24C0212
Location:0.1 MI E/O WOODBINE
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:10.2 ft. [3.1 m]
Total length:20.7 ft. [6.3 m]
Roadway width between curbs:64.0 ft. [19.5 m]
Deck width edge-to-edge:75.1 ft. [22.9 m]
Owner:City or Municipal Highway Agency [04]
Year built:1960
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Number of main spans:2
Main spans material:Concrete continuous [2]
Main spans design:Culvert [19]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: January 2017

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:37,800 [as of 2009]
Truck traffic:10% of total traffic
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Culvert condition:Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:81.5

Previous Inspections

DateConditionCulvert ConditionADTSuff. Rating
January 2017Good7 out of 103780081.5
January 2015Good7 out of 103780081.5
May 2010Good8 out of 102519091.4
July 2006Good8 out of 102519091.4
November 2003Good8 out of 102519091.4
April 2002Good8 out of 102519091.4
May 1999Good7 out of 102519091.4
August 1994Good7 out of 102519091.1
August 1992Good7 out of 102519091.1
March 1990Good7 out of 102519091.1

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Culvert
Reinforced Concrete Culvertlinear ft.4641500
Wearing Surfacessq. ft.115115000