Share:

I 880 over UP RR SPUR,FRUITVALE AVE

Map

Coordinates:
+37.77167, -122.22500
37°46'18" N, 122°13'30" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:I 880 over UP RR SPUR,FRUITVALE AVE
Structure number:33 0041
Location:04-ALA-880-28.24-OAK
Purpose:Carries highway over highway and railroad
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:85.0 ft. [25.9 m]
Total length:1410.2 ft. [429.8 m]
Roadway width between curbs:101.7 ft. [31.0 m]
Deck width edge-to-edge:109.9 ft. [33.5 m]
Vertical clearance below bridge:19.4 ft. [5.9 m]
Owner:State Highway Agency [01]
Year built:1948
Year reconstructed:1963
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:23
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Integral Concrete (separate non-modified layer of concrete added to structural deck) [2]

Latest Available Inspection: January 2017

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:225,000 [as of 2009]
Truck traffic:14% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Operating rating:61.7 tons [56.1 metric tons]
Inventory rating:36.7 tons [33.4 metric tons]
Sufficiency rating:92.0

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
January 201792.0GoodGoodGoodGoodFO225000
January 201592.0FairVery GoodSatisfactoryGoodFO225000
January 201392.0FairSatisfactorySatisfactoryGoodFO225000
January 201192.0FairSatisfactorySatisfactoryGoodFO240000
January 200991.0FairFairSatisfactoryGoodFO240000
January 200791.0FairFairSatisfactoryGoodFO240000
January 200593.0FairFairGoodGoodFO210000
February 200393.0FairFairGoodGoodFO210000
February 200194.0FairSatisfactoryGoodGoodFO185000
June 199998.0FairSatisfactoryGoodGood-185000
February 199593.0PoorPoorSatisfactoryGoodSD176300
June 199393.0PoorPoorSatisfactoryGoodSD162400
February 199193.0PoorPoorSatisfactoryGoodSD162400

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Superstructure
Steel Girder/Beamlinear ft.7,73807,73800
Steel Protective Coatingsq. ft.1,09259250000
Deck
Reinforced Concrete Decksq. ft.23,22022,98623400
Wearing Surfacessq. ft.22,57522,575000
Superstructure
Steel Pin or Pin & Hangar Assemblyeach1661290370
Steel Protective Coatingsq. ft.85533200
Substructure
Reinforced Concrete Columneach108010800
Reinforced Concrete Abutmentlinear ft.6767000
Reinforced Concrete Pier Caplinear ft.1,4761,4661000
Joints
Pourable Jointlinear ft.776776000
Bearings
Elastomeric Bearingeach8808800
Fixed Bearingeach432432000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.1,2901,2800100