Share:

BROADWAY over GOLDEN GATE AVE

Map

Coordinates:
+37.84944, -122.23972
37°50'58" N, 122°14'23" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:BROADWAY over GOLDEN GATE AVE
Structure number:33 0132Y
Location:04-ALA-024-R4.43-OAK
Purpose:Carries highway and pedestrian walkway over highway
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:54.1 ft. [16.5 m]
Total length:146.3 ft. [44.6 m]
Roadway width between curbs:44.0 ft. [13.4 m]
Deck width edge-to-edge:56.4 ft. [17.2 m]
Vertical clearance below bridge:12.8 ft. [3.9 m]
Skew angle:28°
Owner:State Highway Agency [01]
Year built:1934
Historic significance:Bridge is possibly eligible for the National Register of Historic Places [3]
Design load:M 13.5 / H 15 [2]
Number of main spans:3
Main spans material:Concrete continuous [2]
Main spans design:Tee beam [04]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: February 2016

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:1,050 [as of 2010]
Truck traffic:2% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Very Good [8 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Equal to present desirable criteria [8]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Operating rating:109.8 tons [99.8 metric tons]
Inventory rating:76.2 tons [69.3 metric tons]
Sufficiency rating:92.9

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
February 201692.9GoodGoodGoodVery GoodFO1050
February 201491.9FairFairGoodGoodFO1050
February 201291.9FairFairGoodGoodFO1050
March 201089.9PoorPoorGoodGoodSD750
January 200889.9PoorPoorGoodGoodSD750
January 200689.9PoorPoorGoodGoodSD750
January 200490.0PoorPoorGoodGoodSD-
November 200190.0PoorPoorGoodGoodSD-
May 200090.0PoorPoorGoodGoodSD-
November 199991.0PoorPoorGoodGoodSD-
November 199794.0GoodGoodGoodGoodFO-
September 199692.0GoodGoodGoodGoodFO-
December 199392.0FairSatisfactorySatisfactorySatisfactoryFO-
September 199192.0FairSatisfactorySatisfactorySatisfactoryFO-

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Superstructure
Reinforced Concrete Girder/Beamlinear ft.180179010
Reinforced Concrete Floor Beamlinear ft.2171477000
Deck
Reinforced Concrete Top Flangesq. ft.7006300700
Wearing Surfacessq. ft.600060000
Substructure
Reinforced Concrete Columneach88000
Reinforced Concrete Abutmentlinear ft.3939000
Reinforced Concrete Pier Caplinear ft.4141000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.9009000