Share:

BALDWIN ST over ELMHURST CREEK

Map

Coordinates:
+37.74889, -122.19583
37°44'56" N, 122°11'45" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:BALDWIN ST over ELMHURST CREEK
Structure number:33C0041
Location:E/O HEGENBERGER RD
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Local (Urban) [19]
Length of largest span:14.1 ft. [4.3 m]
Total length:58.1 ft. [17.7 m]
Roadway width between curbs:31.8 ft. [9.7 m]
Deck width edge-to-edge:51.2 ft. [15.6 m]
Skew angle:13°
Owner:City or Municipal Highway Agency [04]
Year built:1964
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Number of main spans:4
Main spans material:Concrete continuous [2]
Main spans design:Tee beam [04]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: September 2016

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:38,929 [as of 2002]
Truck traffic:2% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Basically intolerable requiring high priority of corrrective action [3]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Operating rating:44.6 tons [40.5 metric tons]
Inventory rating:26.7 tons [24.3 metric tons]
Sufficiency rating:81.3
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$463,000

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
September 201681.3GoodGoodGoodGoodFO38929
September 201469.5FairGoodGoodFairFO38929
October 201239.1PoorSatisfactoryGoodPoorSD38929
October 201097.0FairGoodGoodSatisfactory-50
October 200897.0FairGoodGoodSatisfactory-50
September 200697.0FairGoodGoodSatisfactory-50
September 200497.0GoodGoodGoodGood-50
September 200297.0GoodGoodGoodGood-50
September 200097.0GoodGoodGoodGood-50
March 199997.0GoodGoodGoodGood-50
November 199897.0GoodGoodGoodGood-50
November 199597.0GoodGoodGoodGood-50
October 199397.0GoodGoodGoodGood-50
June 199197.0GoodGoodGoodGood-50