Share:

ROUTE 180 over S99-E180 CONNECTOR

Map

Coordinates:
+36.73993, -119.81685
36°44'24" N, 119°49'01" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:ROUTE 180 over S99-E180 CONNECTOR
Structure number:42 0391L
Location:06-FRE-180-R56.17-FRE
Purpose:Carries highway over highway
Route classification:Principal Arterial - Other Freeways or Expressways (Urban) [12]
Length of largest span:145.0 ft. [44.2 m]
Total length:145.0 ft. [44.2 m]
Roadway width between curbs:55.1 ft. [16.8 m]
Deck width edge-to-edge:58.7 ft. [17.9 m]
Vertical clearance below bridge:16.4 ft. [5.0 m]
Skew angle:19°
Owner:State Highway Agency [01]
Year built:2003
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Main span material:Prestressed concrete [5]
Main span design:Box Beam or girders - Single or Spread [06]
Deck type:Concrete Cast-in-Place [1]

Latest Available Inspection: January 2018

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:8,000 [as of 1999]
Truck traffic:4% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Equal to present minimum criteria [6]
Underclearances appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:97.6

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
January 2018FairFairGoodGood800097.6
January 2016FairSatisfactoryVery GoodVery Good800098.6
April 2014FairSatisfactoryVery GoodGood800098.6
February 2012GoodGoodVery GoodGood800099.6
March 2010GoodGoodVery GoodGood330099.9
February 2008GoodGoodVery GoodGood330099.9
February 2006GoodGoodVery GoodGood330099.9

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Prestressed Concrete Closed Web/Box Girderlinear ft.4444000
Deck
Reinforced Concrete Top Flangesq. ft.790079000
Substructure
Reinforced Concrete Abutmentlinear ft.7272000
Joints
Compression Jointlinear ft.3636000
Bearings
Enclosed/Concealed Bearingeach22000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.8888000