Share:

ROUTE 180 over TEILMAN AVENUE

Map

Coordinates:
+36.73849, -119.82219
36°44'19" N, 119°49'20" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:ROUTE 180 over TEILMAN AVENUE
Structure number:42 0421L
Location:06-FRE-180-R55.85-FRE
Purpose:Carries highway over highway
Route classification:Principal Arterial - Other Freeways or Expressways (Urban) [12]
Length of largest span:129.6 ft. [39.5 m]
Total length:129.6 ft. [39.5 m]
Roadway width between curbs:85.6 ft. [26.1 m]
Deck width edge-to-edge:90.2 ft. [27.5 m]
Vertical clearance below bridge:16.4 ft. [5.0 m]
Skew angle:
Owner:State Highway Agency [01]
Year built:2003
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Main span material:Prestressed concrete [5]
Main span design:Box Beam or girders - Single or Spread [06]
Deck type:Concrete Cast-in-Place [1]

Latest Available Inspection: January 2018

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:8,000 [as of 1998]
Truck traffic:4% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Superior to present desirable criteria [9]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:78.5
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$1,827,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
January 2018FairFairFairGood800078.5
January 2016FairSatisfactoryGoodVery Good800090.6
April 2014GoodGoodVery GoodGood800090.6
February 2012GoodGoodVery GoodGood800093.6
March 2010GoodGoodVery GoodGood375093.8
February 2008GoodGoodVery GoodGood375093.8
January 2006GoodGoodVery GoodGood375093.8

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Prestressed Concrete Closed Web/Box Girderlinear ft.3935040
Deck
Reinforced Concrete Top Flangesq. ft.1,08801,08800
Substructure
Reinforced Concrete Abutmentlinear ft.8080000
Joints
Compression Jointlinear ft.5454000
Bearings
Enclosed/Concealed Bearingeach22000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.7979000