STATE ROUTE 72 over SAN GABRIEL RIVER
This bridge is no longer in the current National Bridge Inventory database, and has likely been demolished or abandoned.
Map
Coordinates:
+33.99667, -118.0733333°59'48" N, 118°04'24" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | STATE ROUTE 72 over SAN GABRIEL RIVER |
Structure number: | 53 0006 |
Location: | 07-LA-072-6.86-PRV |
Purpose: | Carries highway overpass over waterway |
Route classification: | Other Principal Arterial (Urban) [14] |
Length of largest span: | 75.1 ft. [22.9 m] |
Total length: | 377.0 ft. [114.9 m] |
Roadway width between curbs: | 84.0 ft. [25.6 m] |
Deck width edge-to-edge: | 96.1 ft. [29.3 m] |
Skew angle: | 24° |
Owner: | State Highway Agency [01] |
Year built: | 1968 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18 / HS 20 [5] |
Number of main spans: | 5 |
Main spans material: | Prestressed concrete continuous [6] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: August 2008
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 26,900 [as of 2000] |
Truck traffic: | 5% of total traffic |
Deck condition: | Good [7 out of 9] |
Superstructure condition: | Very Good [8 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Superior to present desirable criteria [9] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Superior to present desirable criteria [9] |
Channel protection: | Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8] |
Scour condition: | Bridge foundations determined to be stable for assessed or calculated scour condition. [5] |
Sufficiency rating: | 95.5 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
August 2008 | Fair | Good | Very Good | Satisfactory | 26900 | 95.5 |
February 2000 | Fair | Satisfactory | Very Good | Satisfactory | 26900 | 95.5 |
May 1992 | Good | Very Good | Very Good | Very Good | 36200 | 95.3 |