Share:

INTERSTATE 405 over BEL AIR CREST RD NORTH

Map

Coordinates:
+34.11046, -118.48132
34°06'38" N, 118°28'53" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:INTERSTATE 405 over BEL AIR CREST RD NORTH
Structure number:53 1464
Location:07-LA-405-35.81-LA
Purpose:Carries highway over highway
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:81.0 ft. [24.7 m]
Total length:203.1 ft. [61.9 m]
Roadway width between curbs:167.3 ft. [51.0 m]
Deck width edge-to-edge:167.3 ft. [51.0 m]
Vertical clearance below bridge:19.7 ft. [6.0 m]
Skew angle:10°
Owner:State Highway Agency [01]
Year built:1962
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Number of main spans:3
Main spans material:Concrete continuous [2]
Main spans design:Box beam or girders - Multiple [05]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: August 2017

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:274,000 [as of 2014]
Truck traffic:10% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Superior to present desirable criteria [9]
Underclearances appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:85.0

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
August 2017GoodGoodGoodGood27400085.0
August 2015GoodVery GoodVery GoodVery Good27400085.0
August 2013GoodGoodGoodGood27400084.0
August 2011GoodGoodGoodGood27400084.0
August 2009GoodGoodGoodGood27400084.0
January 2008FairSatisfactoryGoodGood27400084.0
July 2006FairSatisfactoryGoodGood27400084.0
February 2004FairSatisfactoryGoodGood27400084.0
December 2001FairSatisfactoryGoodGood26870096.0
January 1998FairSatisfactoryGoodGood26870098.0
January 1996GoodGoodVery GoodVery Good27650098.0
April 1994GoodGoodVery GoodVery Good27650098.0
April 1992GoodGoodVery GoodVery Good27520098.0
February 1990GoodGoodVery GoodVery Good27520098.0

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Reinforced Concrete Closed Web/Box Girderlinear ft.6262000
Prestressed Concrete Girder/Beamlinear ft.278278000
Deck
Reinforced Concrete Top Flangesq. ft.3,1353,133200
Wearing Surfacessq. ft.30030
Substructure
Reinforced Concrete Columneach88000
Reinforced Concrete Abutmentlinear ft.103103000
Reinforced Concrete Pileeach1111000
Joints
Pourable Jointlinear ft.3131000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.186186000