Share:

FAIRFAX-W10 ONRAMP over BALLONA CRK & ACCESS RD

Map

Coordinates:
+34.03631, -118.37334
34°02'11" N, 118°22'24" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:FAIRFAX-W10 ONRAMP over BALLONA CRK & ACCESS RD
Structure number:53 1671K
Location:07-LA-010-R9.10-LA
Purpose:Carries highway over waterway
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:115.8 ft. [35.3 m]
Total length:353.7 ft. [107.8 m]
Roadway width between curbs:27.9 ft. [8.5 m]
Deck width edge-to-edge:34.1 ft. [10.4 m]
Skew angle:30°
Owner:State Highway Agency [01]
Year built:1964
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 18 / H 20 [4]
Number of main spans:4
Main spans material:Concrete continuous [2]
Main spans design:Box beam or girders - Multiple [05]
Deck type:Concrete Cast-in-Place [1]

Latest Available Inspection: August 2016

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:10,700 [as of 2009]
Truck traffic:1% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Basically intolerable requiring high priority of corrrective action [3]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:74.4
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$1,876,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
August 2016GoodGoodGoodGood1070074.4
August 2014GoodVery GoodVery GoodVery Good1070076.5
August 2012GoodGoodGoodGood1070076.7
August 2010FairFairGoodGood1070075.7
August 2008FairFairGoodGood1070075.7
August 2006FairFairGoodGood1070075.7
November 2004FairFairGoodGood1070075.7
October 2002FairFairGoodGood950075.8
April 2001FairFairGoodGood950075.8
February 2000GoodGoodGoodGood950072.8
July 1997GoodGoodGoodGood950072.8
December 1993GoodGoodVery GoodVery Good950075.0
November 1991GoodGoodVery GoodVery Good950075.0

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Reinforced Concrete Closed Web/Box Girderlinear ft.108108000
Deck
Reinforced Concrete Top Flangesq. ft.1,1171,117000
Concrete Protective Coatingsq. ft.1,1171,117000
Substructure
Reinforced Concrete Columneach11000
Reinforced Concrete Abutmentlinear ft.2222000
Prestressed Concrete Pileeach11000
Bridge Rail
Other Material Bridge Raillinear ft.216216000