Share:

ROUTE 118 over SAN FERNANDO RD

Map

Coordinates:
+34.27211, -118.42889
34°16'20" N, 118°25'44" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:ROUTE 118 over SAN FERNANDO RD
Structure number:53 2095
Location:07-LA-118-R12.40-LA
Purpose:Carries highway over highway and railroad
Route classification:Principal Arterial - Other Freeways or Expressways (Urban) [12]
Length of largest span:127.6 ft. [38.9 m]
Total length:253.9 ft. [77.4 m]
Roadway width between curbs:195.5 ft. [59.6 m]
Deck width edge-to-edge:201.1 ft. [61.3 m]
Vertical clearance below bridge:19.7 ft. [6.0 m]
Owner:State Highway Agency [01]
Year built:1976
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:2
Main spans material:Concrete continuous [2]
Main spans design:Box beam or girders - Multiple [05]
Deck type:Concrete Cast-in-Place [1]

Latest Available Inspection: July 2016

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:133,000 [as of 2009]
Truck traffic:3% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Superior to present desirable criteria [9]
Underclearances appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:78.6

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
July 2016GoodGoodGoodGood13300078.6
July 2014GoodVery GoodVery GoodVery Good13300080.6
July 2012GoodGoodGoodGood13300080.6
January 2011FairSatisfactoryGoodGood12400081.5
July 2008FairSatisfactoryGoodGood12400081.5
August 2006GoodGoodGoodGood12400081.5
January 2005GoodGoodGoodGood12400081.5
January 2003GoodGoodGoodGood13700080.2
September 2001GoodGoodGoodGood9860088.5
March 2001GoodGoodGoodGood9860088.5
January 1999GoodGoodGoodGood9860088.5
January 1997GoodGoodGoodGood9750088.6
February 1995GoodVery GoodVery GoodVery Good9750088.3
January 1993GoodVery GoodVery GoodVery Good9600088.4
June 1991GoodVery GoodVery GoodVery Good9600088.4

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Reinforced Concrete Closed Web/Box Girderlinear ft.232232000
Deck
Reinforced Concrete Top Flangesq. ft.5,1205,0903000
Concrete Protective Coatingsq. ft.4,5204,520000
Substructure
Reinforced Concrete Columneach55000
Reinforced Concrete Abutmentlinear ft.122122000
Joints
Pourable Jointlinear ft.174174000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.233233000