Share:

STATE ROUTE 118 over PACOIMA WASH

Map

Coordinates:
+34.26707, -118.44042
34°16'01" N, 118°26'26" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:STATE ROUTE 118 over PACOIMA WASH
Structure number:53 2186
Location:07-LA-118-R11.65L-LA
Purpose:Carries highway over waterway
Route classification:Principal Arterial - Other Freeways or Expressways (Urban) [12]
Length of largest span:20.3 ft. [6.2 m]
Total length:40.7 ft. [12.4 m]
Roadway width between curbs:200.1 ft. [61.0 m]
Deck width edge-to-edge:435.7 ft. [132.8 m]
Skew angle:35°
Owner:State Highway Agency [01]
Year built:1969
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:2
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Not applicable [N]

Latest Available Inspection: July 2016

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:205,000 [as of 1999]
Truck traffic:8% of total traffic
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Superior to present desirable criteria [9]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Culvert condition:Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:85.0

Previous Inspections

DateConditionCulvert ConditionADTSuff. Rating
July 2016Good7 out of 1020500085.0
July 2014Good8 out of 1020500085.0
January 2011Good8 out of 1020500085.0
August 2006Good8 out of 1020500085.0
January 2005Good8 out of 1020500085.0
January 2003Good8 out of 1013700087.2
March 2001Good8 out of 1017030085.0
January 1999Good8 out of 1017030085.0
January 1997Good8 out of 109750073.9
February 1995Good8 out of 109750076.1
January 1993Good8 out of 109600076.3
June 1991Good8 out of 109600076.3

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Culvert
Reinforced Concrete Culvertlinear ft.326322400