Share:

RTE 103 over ANAHEIM STREET OH

Map

Coordinates:
+33.78500, -118.22500
33°47'06" N, 118°13'30" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:RTE 103 over ANAHEIM STREET OH
Structure number:53 2627
Location:07-LA-103-0.90-LA
Purpose:Carries highway over highway and railroad
Route classification:Principal Arterial - Other Freeways or Expressways (Urban) [12]
Length of largest span:119.1 ft. [36.3 m]
Total length:1544.0 ft. [470.6 m]
Roadway width between curbs:62.7 ft. [19.1 m]
Deck width edge-to-edge:70.9 ft. [21.6 m]
Vertical clearance below bridge:21.0 ft. [6.4 m]
Skew angle:35°
Owner:State Highway Agency [01]
Year built:1947
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Number of main spans:19
Main spans material:Steel [3]
Main spans design:Slab [01]
Deck type:Concrete Cast-in-Place [1]

Latest Available Inspection: February 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:15,200 [as of 2014]
Truck traffic:18% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Operating rating:64.8 tons [58.9 metric tons]
Inventory rating:42.9 tons [39.0 metric tons]
Sufficiency rating:88.7

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
February 201688.7FairSatisfactorySatisfactoryGoodFO15200
February 201474.2PoorPoorFairGoodSD15200
February 201274.2PoorPoorFairGoodSD15200
February 201074.2PoorPoorFairGoodSD15200
June 200874.2PoorPoorFairGoodSD15200
April 200774.2PoorPoorFairGoodSD15200
December 200574.2PoorPoorFairGoodSD15200
June 200474.2PoorPoorFairGoodSD15200
April 200274.2PoorPoorFairGoodSD15200
February 200274.2PoorPoorFairGoodSD15200
April 199876.3PoorPoorFairGoodSD15200
September 199776.3PoorPoorFairGoodSD15200
April 199490.2GoodGoodVery GoodVery Good-18000
February 199289.8GoodGoodVery GoodVery Good-20500

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Superstructure
Steel Girder/Beamlinear ft.2,60102,60010
Steel Protective Coatingsq. ft.300300000
Steel Pin or Pin & Hangar Assemblyeach108010800
Steel Protective Coatingsq. ft.3030000
Substructure
Steel Columneach1201200
Steel Protective Coatingsq. ft.1212000
Reinforced Concrete Columneach9494000
Reinforced Concrete Abutmentlinear ft.8080000
Steel Pileeach11000
Timber Pileeach11000
Joints
Pourable Jointlinear ft.122121001
Open Jointlinear ft.6161000
Other Jointlinear ft.488488000
Bearings
Movable Bearingeach117117000
Steel Protective Coatingsq. ft.117117000
Fixed Bearingeach117117000
Steel Protective Coatingsq. ft.117117000
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.1,083001,0803
Steel Protective Coatingsq. ft.300300000
Deck
Reinforced Concrete Slabsq. ft.9,50709,50700