SAN FERNANDO RD over BEACON WASH

Map

Coordinates:
+34.24949, -118.40440
34°14'58" N, 118°24'16" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:SAN FERNANDO RD over BEACON WASH
Structure number:53C0301
Location:0.1 MI NW BRANFORD ST
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:12.1 ft. [3.7 m]
Total length:40.0 ft. [12.2 m]
Roadway width between curbs:54.5 ft. [16.6 m]
Deck width edge-to-edge:66.9 ft. [20.4 m]
Owner:City or Municipal Highway Agency [04]
Year built:1927
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 9 / H 10 [1]
Number of main spans:3
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Not applicable [N]

Latest Available Inspection: December 2016

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:20,000 [as of 2011]
Truck traffic:2% of total traffic
Structural appraisal:Meets minimum tolerable limits to be left in place as is [4]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Culvert condition:Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:54.3

Previous Inspections

DateConditionCulvert ConditionADTSuff. Rating
December 2016Good7 out of 102000054.3
December 2014Good7 out of 102000054.3
December 2012Good8 out of 102000070.9
March 2011Good8 out of 102000070.9
December 2008Good8 out of 102200070.7
March 2007Good8 out of 102200070.7
May 2005Good8 out of 102200070.7
April 2001Good7 out of 101550079.2
April 1999Good7 out of 101550079.2
May 1997Good8 out of 101550079.2
January 1995Good7 out of 101550079.2
October 1993Good8 out of 101550079.6
December 1990Good8 out of 101550079.6

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Culvert
Reinforced Concrete Culvertlinear ft.2018200
Wearing Surfacessq. ft.203002030