ALONDRA BLVD over COMPTON CRK
Map
Coordinates:
+33.88846, -118.2295033°53'18" N, 118°13'46" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | ALONDRA BLVD over COMPTON CRK |
Structure number: | 53C0460 |
Location: | 0.5MI E/O WILMINGTON AVE |
Purpose: | Carries highway and pedestrian walkway over waterway |
Route classification: | Other Principal Arterial (Urban) [14] |
Length of largest span: | 34.5 ft. [10.5 m] |
Total length: | 76.1 ft. [23.2 m] |
Roadway width between curbs: | 60.0 ft. [18.3 m] |
Deck width edge-to-edge: | 73.2 ft. [22.3 m] |
Skew angle: | 30° |
Owner: | City or Municipal Highway Agency [04] |
Year built: | 1938 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18 / HS 20 [5] |
Number of main spans: | 2 |
Main spans material: | Steel [3] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Latest Available Inspection: April 2017
Good/Fair/Poor Condition: | Poor |
Status: | Open, no restriction [A] |
Average daily traffic: | 29,362 [as of 2012] |
Truck traffic: | 4% of total traffic |
Deck condition: | Poor [4 out of 9] |
Superstructure condition: | Fair [5 out of 9] |
Substructure condition: | Good [7 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Water adequacy appraisal: | Superior to present desirable criteria [9] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | There are no noticeable or noteworthy deficiencies which affect the condition of the channel. [9] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 66.0 |
Recommended work: | Bridge rehabilitation because of general structure deterioration or inadequate strength. [35] |
Estimated cost of work: | $2,343,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
April 2017 | Poor | Poor | Fair | Good | 29362 | 66.0 |
April 2015 | Poor | Poor | Fair | Good | 29362 | 66.0 |
April 2013 | Poor | Serious | Fair | Satisfactory | 29362 | 63.7 |
April 2011 | Poor | Serious | Fair | Satisfactory | 27700 | 66.2 |
June 2009 | Poor | Poor | Fair | Satisfactory | 27700 | 68.5 |
June 2007 | Poor | Serious | Fair | Satisfactory | 27700 | 67.4 |
May 2005 | Fair | Fair | Fair | Satisfactory | 27700 | 71.9 |
June 2003 | Poor | Poor | Fair | Satisfactory | 27700 | 69.6 |
March 2001 | Fair | Satisfactory | Fair | Satisfactory | 18000 | 75.8 |
March 1998 | Poor | Serious | Serious | Satisfactory | 18000 | 34.4 |
February 1996 | Good | Good | Good | Good | 18000 | 87.5 |
January 1994 | Fair | Good | Satisfactory | Good | 18000 | 87.7 |
January 1992 | Fair | Good | Satisfactory | Good | 18000 | 87.7 |
February 1990 | Good | Good | Good | Good | 16300 | 88.1 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 232 | 0 | 232 | 0 | 0 |
Steel Protective Coating | sq. ft. | 495 | 0 | 0 | 0 | 495 |
Deck |
Reinforced Concrete Deck | sq. ft. | 516 | 0 | 424 | 92 | 0 |
Substructure |
Reinforced Concrete Pier Wall | linear ft. | 29 | 29 | 0 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 58 | 58 | 0 | 0 | 0 |
Timber Pile | each | 1 | 1 | 0 | 0 | 0 |
Joints |
Pourable Joint | linear ft. | 63 | 0 | 0 | 63 | 0 |
Bearings |
Movable Bearing | each | 20 | 0 | 20 | 0 | 0 |
Steel Protective Coating | sq. ft. | 20 | 0 | 0 | 0 | 20 |
Fixed Bearing | each | 20 | 0 | 20 | 0 | 0 |
Steel Protective Coating | sq. ft. | 20 | 0 | 0 | 0 | 20 |
Bridge Rail |
Reinforced Concrete Bridge Rail | linear ft. | 46 | 12 | 11 | 23 | 0 |