Share:

VERMONT AVE over DOMINGUEZ CHANNEL

Map

Coordinates:
+33.87000, -118.29083
33°52'12" N, 118°17'27" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:VERMONT AVE over DOMINGUEZ CHANNEL
Structure number:53C0664
Location:1/4 MI S/O ARTESIA BLVD
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:25.3 ft. [7.7 m]
Total length:78.1 ft. [23.8 m]
Roadway width between curbs:80.1 ft. [24.4 m]
Deck width edge-to-edge:91.9 ft. [28.0 m]
Skew angle:15°
Owner:City or Municipal Highway Agency [04]
Year built:1958
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 13.5 / H 15 [2]
Number of main spans:3
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Not applicable [N]

Latest Available Inspection: April 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:38,000 [as of 2006]
Truck traffic:2% of total traffic
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Superior to present desirable criteria [9]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Culvert condition:Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:44.6 tons [40.5 metric tons]
Inventory rating:26.7 tons [24.3 metric tons]
Sufficiency rating:83.6

Previous Inspections

DateSuff. RatingConditionCulvert ConditionSD/FOADT
April 201683.6Fair6 out of 10-38000
April 201471.7Fair5 out of 10-38000
April 201291.7Good7 out of 10-38000
May 201091.7Good7 out of 10-38000
April 200891.7Good7 out of 10-38000
September 200491.7Good8 out of 10-38000
November 200094.2Good7 out of 10-19600
October 199894.2Good7 out of 10-19600
November 199694.2Good7 out of 10-19600
April 199578.7Good7 out of 10-19600
January 199378.4Good7 out of 10-19600
January 199178.4Good7 out of 10-19600