Share:

SATICOY STREET over PACOIMA WASH

Map

Coordinates:
+34.20835, -118.45361
34°12'30" N, 118°27'13" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:SATICOY STREET over PACOIMA WASH
Structure number:53C1316
Location:0.3 MI W VAN NUYS BLVD
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Minor Arterial (Urban) [16]
Length of largest span:18.0 ft. [5.5 m]
Total length:55.1 ft. [16.8 m]
Roadway width between curbs:65.9 ft. [20.1 m]
Deck width edge-to-edge:86.0 ft. [26.2 m]
Skew angle:47°
Owner:City or Municipal Highway Agency [04]
Year built:1933
Year reconstructed:1972
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 9 / H 10 [1]
Number of main spans:2
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Not applicable [N]

Latest Available Inspection: November 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:23,500 [as of 2007]
Truck traffic:1% of total traffic
Structural appraisal:Meets minimum tolerable limits to be left in place as is [4]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Culvert condition:Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:68.2

Previous Inspections

DateConditionCulvert ConditionADTSuff. Rating
November 2016Fair6 out of 102350068.2
November 2014Good7 out of 102350068.2
November 2012Good7 out of 102350092.7
April 2011Good7 out of 102350092.7
November 2008Good7 out of 101990093.2
July 2005Good7 out of 101990094.2
July 2000Good7 out of 101990094.2
July 1998Good7 out of 101990094.2
July 1996Good7 out of 101990094.2
May 1994Good7 out of 101990094.0
April 1992Good7 out of 101990094.0
April 1990Good7 out of 101990094.0