Share:

SEVENTH ST over BNSF RY, L A RIVER, UPRR

Map

Coordinates:
+34.03447, -118.22865
34°02'04" N, 118°13'43" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:SEVENTH ST over BNSF RY, L A RIVER, UPRR
Structure number:53C1321
Location:0.3 MI W/O US 101
Purpose:Carries highway and pedestrian walkway over railroad and waterway
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:91.9 ft. [28.0 m]
Total length:1000.0 ft. [304.8 m]
Roadway width between curbs:56.1 ft. [17.1 m]
Deck width edge-to-edge:70.9 ft. [21.6 m]
Vertical clearance below bridge:19.7 ft. [6.0 m]
Skew angle:10°
Owner:City or Municipal Highway Agency [04]
Year built:1927
Historic significance:Bridge is eligible for the National Register of Historic Places [2]
Design load:M 18 / H 20 [4]
Number of main spans:3
Main spans material:Concrete continuous [2]
Main spans design:Arch - Deck [11]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: July 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:26,666 [as of 2010]
Truck traffic:3% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Underclearances appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:78.5

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
July 2016FairGoodGoodFair2666678.5
July 2014GoodGoodGoodGood2666690.1
July 2012PoorPoorSatisfactoryGood2666687.0
October 2010PoorPoorSatisfactoryGood2500087.2
July 2008PoorPoorSatisfactoryGood2500087.2
April 2005GoodGoodGoodGood2500090.4
April 2001GoodGoodGoodGood3040090.6
March 1999GoodGoodGoodGood3040090.6
November 1997GoodGoodGoodGood3040090.6
March 1996FairGoodFairFair3040078.9
March 1992FairGoodFairFair3040078.5
March 1990FairGoodFairFair3040078.5

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Reinforced Concrete Closed Web/Box Girderlinear ft.3803800
Reinforced Concrete Girder/Beamlinear ft.1,8961,68621000
Deck
Reinforced Concrete Decksq. ft.5,2104,32488600
Wearing Surfacessq. ft.5,2104,69052000
Superstructure
Reinforced Concrete Archlinear ft.1661036300
Substructure
Reinforced Concrete Columneach6363000
Reinforced Concrete Pier Walllinear ft.5105100
Reinforced Concrete Abutmentlinear ft.4444000
Reinforced Concrete Pile Cap/Footinglinear ft.11000
Timber Pileeach11000
Reinforced Concrete Pier Caplinear ft.38427910500
Joints
Open Jointlinear ft.11000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.630628200