Share:

TEMPLE STREET over PEDESTRIAN WALKWAY

Map

Coordinates:
+34.05339, -118.24141
34°03'12" N, 118°14'29" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:TEMPLE STREET over PEDESTRIAN WALKWAY
Structure number:53C1780
Location:50' EAST OF MAIN ST
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:51.8 ft. [15.8 m]
Total length:265.1 ft. [80.8 m]
Roadway width between curbs:62.0 ft. [18.9 m]
Deck width edge-to-edge:86.6 ft. [26.4 m]
Vertical clearance above deck:16.1 ft. [4.9 m]
Owner:City or Municipal Highway Agency [04]
Year built:1975
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Main span material:Concrete [1]
Main span design:Box Beam or girders - Single or Spread [06]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: September 2016

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:15,000 [as of 2007]
Truck traffic:2% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:98.6

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
September 2016GoodGoodGoodGood1500098.6
September 2012GoodGoodGoodGood1500098.6
March 2011GoodGoodGoodGood1500098.6
September 2008GoodGoodGoodGood1500098.6
April 2005GoodGoodGoodGood1500098.6
January 1999GoodGoodGoodGood1338998.7
March 1997GoodGoodGoodGood1338998.7
December 1994GoodGoodGoodGood1338998.7
December 1992Good-Very GoodVery Good1338999.0
December 1990GoodVery GoodVery GoodVery Good1338983.8

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Reinforced Concrete Girder/Beamlinear ft.11000
Deck
Reinforced Concrete Top Flangesq. ft.2,1332,133000
Wearing Surfacessq. ft.1,5271,527000
Substructure
Reinforced Concrete Columneach11000