Share:

PASADENA AVE over ARROYO SECO CHANNEL

Map

Coordinates:
+34.08617, -118.21279
34°05'10" N, 118°12'46" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:PASADENA AVE over ARROYO SECO CHANNEL
Structure number:53C1876
Location:AT I-110
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Principal Arterial - Other (Rural) [02]
Length of largest span:66.9 ft. [20.4 m]
Total length:79.1 ft. [24.1 m]
Roadway width between curbs:51.8 ft. [15.8 m]
Deck width edge-to-edge:65.6 ft. [20.0 m]
Skew angle:27°
Owner:City or Municipal Highway Agency [04]
Year built:1940
Historic significance:Bridge is eligible for the National Register of Historic Places [2]
Design load:M 9 / H 10 [1]
Main span material:Concrete continuous [2]
Main span design:Tee beam [04]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: May 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:15,500 [as of 2005]
Truck traffic:1% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Superior to present desirable criteria [9]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:87.5

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
May 2017FairFairGoodGood1550087.5
May 2015GoodGoodVery GoodGood1550093.4
May 2013FairSatisfactoryGoodSatisfactory1550093.4
May 2011FairSatisfactoryGoodGood1550092.7
February 2009FairSatisfactoryGoodGood1550092.7
September 2006FairSatisfactoryGoodGood1550092.7
February 2005FairSatisfactoryGoodGood1550092.7
May 2001GoodGoodGoodGood853176.4
May 1998GoodGoodGoodGood853176.4
November 1995FairSatisfactoryGoodGood853176.4
September 1993GoodVery GoodGoodGood853176.1
September 1991GoodVery GoodGoodGood853176.1

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Reinforced Concrete Girder/Beamlinear ft.102102000
Deck
Reinforced Concrete Top Flangesq. ft.38032220380
Wearing Surfacessq. ft.38002001800
Substructure
Reinforced Concrete Abutmentlinear ft.8075500
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.48361200
Steel Protective Coatingsq. ft.2418600