Share:

E8-N163 & S163-E8 over STATE ROUTE 163

Map

Coordinates:
+32.76200, -117.16379
32°45'43" N, 117°09'50" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:E8-N163 & S163-E8 over STATE ROUTE 163
Structure number:57 0223G
Location:11-SD-008-2.41-SD
Purpose:Carries highway over highway
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:130.9 ft. [39.9 m]
Total length:248.0 ft. [75.6 m]
Roadway width between curbs:47.9 ft. [14.6 m]
Deck width edge-to-edge:51.2 ft. [15.6 m]
Vertical clearance below bridge:16.4 ft. [5.0 m]
Skew angle:99°
Owner:State Highway Agency [01]
Year built:1988
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Number of main spans:2
Main spans material:Prestressed concrete continuous [6]
Main spans design:Box beam or girders - Multiple [05]
Deck type:Concrete Cast-in-Place [1]

Latest Available Inspection: February 2018

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:27,000 [as of 2009]
Truck traffic:1% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Better than present minimum criteria [7]
Underclearances appraisal:Meets minimum tolerable limits to be left in place as is [4]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:93.4

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
February 2018GoodGoodGoodGood2700093.4
April 2016GoodGoodVery GoodGood2700093.4
April 2014FairFairVery GoodSatisfactory2700092.4
April 2012FairSatisfactoryVery GoodGood2700093.4
May 2010FairSatisfactoryVery GoodGood2700093.4
April 2008FairSatisfactoryVery GoodGood2700093.4
April 2006GoodGoodVery GoodGood2700093.4
June 2004GoodGoodVery GoodGood1980094.1
August 2002GoodGoodVery GoodGood1980094.1
September 2000GoodGoodVery GoodGood1980094.1
June 1998GoodGoodVery GoodGood1980096.1
June 1996GoodExcellentExcellentExcellent1980094.5
October 1994GoodExcellentExcellentExcellent1980094.5
September 1992GoodExcellentExcellentExcellent1980096.5

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Prestressed Concrete Closed Web/Box Girderlinear ft.7676000
Deck
Reinforced Concrete Top Flangesq. ft.1,1791,0948500
Substructure
Reinforced Concrete Columneach22000
Reinforced Concrete Abutmentlinear ft.3936300
Joints
Compression Jointlinear ft.5950900
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.150150000