Share:

S5-E52 CONNECTOR over MTDB,BNSF RY,AMTRAK,ROSE

Map

Coordinates:
+32.83771, -117.23346
32°50'16" N, 117°14'00" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:S5-E52 CONNECTOR over MTDB,BNSF RY,AMTRAK,ROSE
Structure number:57 0519F
Location:11-SD-005-R25.93-SD
Purpose:Carries highway over railroad and waterway
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:100.1 ft. [30.5 m]
Total length:243.1 ft. [74.1 m]
Roadway width between curbs:34.1 ft. [10.4 m]
Deck width edge-to-edge:38.1 ft. [11.6 m]
Vertical clearance below bridge:42.7 ft. [13.0 m]
Skew angle:
Owner:State Highway Agency [01]
Year built:1966
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Number of main spans:3
Main spans material:Concrete continuous [2]
Main spans design:Box beam or girders - Multiple [05]
Deck type:Concrete Cast-in-Place [1]

Latest Available Inspection: May 2017

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:27,500 [as of 2010]
Truck traffic:2% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Better than present minimum criteria [7]
Underclearances appraisal:Superior to present desirable criteria [9]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:91.6

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
May 2017GoodGoodGoodGood2750091.6
September 2015GoodVery GoodVery GoodVery Good2750091.6
September 2013FairFairGoodGood2750090.5
October 2011FairFairGoodGood2750090.5
October 2009FairFairGoodGood1330093.9
December 2007FairSatisfactoryGoodGood1330094.9
January 2006FairSatisfactoryGoodGood1330094.9
November 2003FairFairGoodGood1330093.9
December 2001FairFairGoodGood1330093.8
March 2000FairSatisfactoryGoodGood1330094.9
December 1997FairSatisfactoryGoodGood1330094.9
September 1995GoodVery GoodVery GoodVery Good1330097.0
November 1991GoodVery GoodVery GoodVery Good1330097.0

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Reinforced Concrete Closed Web/Box Girderlinear ft.7474000
Deck
Reinforced Concrete Top Flangesq. ft.770770000
Concrete Protective Coatingsq. ft.770770000
Substructure
Reinforced Concrete Abutmentlinear ft.2323000
Steel Pileeach11000
Bridge Rail
Other Material Bridge Raillinear ft.148145300