Share:

FRIARS RD over ESCALA APARTMENT VILLAGE

Map 

Coordinates:
+32.78222, -117.13000
32°46'56" N, 117°07'48" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:FRIARS RD over ESCALA APARTMENT VILLAGE
Structure number:57C0294
Location:0.2 MI E OF FENTON PKWY
Purpose:Carries highway over relief for waterway
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:15.1 ft. [4.6 m]
Total length:33.1 ft. [10.1 m]
Roadway width between curbs:82.0 ft. [25.0 m]
Deck width edge-to-edge:118.1 ft. [36.0 m]
Owner:City or Municipal Highway Agency [04]
Year built:1968
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 13.5 / H 15 [2]
Number of main spans:2
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Not applicable [N]

Latest Available Inspection: September 2016 

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:27,200 [as of 2011]
Truck traffic:1% of total traffic
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:There are no noticeable or noteworthy deficiencies which affect the condition of the channel. [9]
Culvert condition:Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:44.6 tons [40.5 metric tons]
Inventory rating:26.7 tons [24.3 metric tons]
Sufficiency rating:81.4

Previous Inspections 

DateSuff. RatingConditionCulvert ConditionSD/FOADT
September 201681.4Good7 out of 10-27200
September 201481.4Good8 out of 10-27200
October 201265.9Fair5 out of 10-38300
March 201265.9Fair5 out of 10-38300
March 201067.0Fair5 out of 10-34500
October 200775.6Fair5 out of 10-34500
November 200575.6Fair5 out of 10-34500
February 200371.0Fair5 out of 10FO34500
January 200170.5Fair5 out of 10FO36300
April 199970.5Fair5 out of 10FO36300
March 199683.3GoodN out of 10FO36300
March 199483.3GoodN out of 10FO36300
January 199283.3GoodN out of 10FO36300