Facts 

Name:HIGHLAND VALLEY RD over SYCAMORE CREEK
Structure number:57C0583
Location:1.8 MI E RTE 1-15
Purpose:Carries highway over waterway
Route classification:Local (Urban) [19]
Length of largest span:4.9 ft. [1.5 m]
Total length:32.2 ft. [9.8 m]
Roadway width between curbs:21.0 ft. [6.4 m]
Deck width edge-to-edge:41.0 ft. [12.5 m]
Owner:City or Municipal Highway Agency [04]
Year built:1983
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Number of main spans:7
Main spans material:Steel [3]
Main spans design:Culvert [19]
Deck type:Not applicable [N]

Latest Available Inspection: October 2015 

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:4,500 [as of 2012]
Truck traffic:1% of total traffic
Structural appraisal:Equal to present desirable criteria [8]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Water adequacy appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Culvert condition:No noticeable or noteworthy deficiencies which affect the condition of the culvert. Insignificant scrape marks caused by drift. [8]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:59.4 tons [54.0 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:75.6
Recommended work:Widening of existing bridge or other major structure without deck rehabilitation or replacement [33]
Estimated cost of work:$174,000

Previous Inspections 

DateSuff. RatingConditionCulvert ConditionSD/FOADT
October 201575.6Good8 out of 10FO4500
March 201375.6Good7 out of 10FO4500
October 200875.8Good7 out of 10FO4000
April 200678.8--FO4000
December 200375.8--FO4000
July 200175.8--FO4000
April 199964.5Fair5 out of 10FO4000
February 199695.1Good8 out of 10-4000
October 199395.1Good8 out of 10-4000
October 199195.1Good8 out of 10-4000