Share:

MONTEZUMA RD over FAIRMOUNT AVE

Map

Coordinates:
+32.77247, -117.09746
32°46'21" N, 117°05'51" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:MONTEZUMA RD over FAIRMOUNT AVE
Structure number:57C0676
Location:0.5MI S/O ROUTE I-8
Purpose:Carries highway over highway
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:134.5 ft. [41.0 m]
Total length:246.1 ft. [75.0 m]
Roadway width between curbs:72.8 ft. [22.2 m]
Deck width edge-to-edge:82.4 ft. [25.1 m]
Vertical clearance below bridge:16.4 ft. [5.0 m]
Skew angle:30°
Owner:City or Municipal Highway Agency [04]
Year built:1996
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Number of main spans:2
Main spans material:Prestressed concrete continuous [6]
Main spans design:Box beam or girders - Multiple [05]
Deck type:Concrete Cast-in-Place [1]

Latest Available Inspection: January 2018

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:23,000 [as of 2016]
Truck traffic:1% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Superior to present desirable criteria [9]
Underclearances appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:90.3

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
January 2018GoodGoodGoodGood2300090.3
September 2016GoodGoodGoodGood2300090.3
September 2014GoodVery GoodVery GoodVery Good2300090.3
February 2013GoodGoodGoodGood2300090.3
March 2012GoodGoodGoodGood2300090.3
March 2010GoodGoodGoodGood2300090.3
October 2007GoodGoodGoodGood2300090.3
October 2005GoodGoodGoodGood2300090.3
November 2003GoodGoodGoodGood2300090.3
December 2001GoodGoodGoodGood-100.0

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Reinforced Concrete Closed Web/Box Girderlinear ft.7575000
Deck
Reinforced Concrete Top Flangesq. ft.1,8601,860000
Substructure
Reinforced Concrete Columneach33000
Reinforced Concrete Abutmentlinear ft.7878000
Steel Pileeach11000
Joints
Compression Jointlinear ft.2929000
Bearings
Enclosed/Concealed Bearingeach22000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.2251952820