Share:

COUNTY ROAD 240 over FLORIDA RIVER

Map

Coordinates:
+37.32561, -107.75471
37°19'32" N, 107°45'17" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:COUNTY ROAD 240 over FLORIDA RIVER
Structure number:067024007.9012A
Location:2.5 MI NE OF CR 225
Purpose:Carries highway over waterway
Route classification:Major Collector (Rural) [07]
Length of largest span:77.4 ft. [23.6 m]
Total length:80.4 ft. [24.5 m]
Roadway width between curbs:31.8 ft. [9.7 m]
Deck width edge-to-edge:32.2 ft. [9.8 m]
Owner:County Highway Agency [02]
Year built:1982
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Main span material:Steel [3]
Main span design:Stringer/Multi-beam or girder [02]
Deck type:Corrugated Steel [6]
Wearing surface:Bituminous [6]

Latest Available Inspection: October 2018

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:2,666 [as of 2017]
Truck traffic:5% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Better than present minimum criteria [7]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:78.5

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
October 2018FairFairFairSatisfactory266678.5
October 2016FairFairFairSatisfactory276379.3
October 2014FairFairFairSatisfactory276380.3
October 2012FairFairFairSatisfactory316379.5
October 2010FairSatisfactorySatisfactorySatisfactory316391.4
November 2008FairSatisfactorySatisfactorySatisfactory302491.7
October 2006FairSatisfactorySatisfactorySatisfactory302491.7
July 2004FairGoodGoodSatisfactory302491.7
August 2002FairGoodGoodSatisfactory302491.3
June 2000FairGoodGoodSatisfactory302491.1
October 1999FairGoodGoodSatisfactory302491.1
October 1998FairGoodGoodSatisfactory302491.1
November 1996FairGoodGoodSatisfactory172394.3
July 1994FairSatisfactoryGoodSatisfactory172394.1
November 1992FairSatisfactoryGoodSatisfactory172395.1
December 1990FairSatisfactoryGoodSatisfactory116093.2

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.644006440
Steel Protective Coatingsq. ft.644006440
Substructure
Steel Columneach1601600
Steel Protective Coatingsq. ft.1600016
Steel Abutmentlinear ft.6464000
Steel Protective Coatingsq. ft.6464000
Steel Pier Caplinear ft.6406400
Steel Protective Coatingsq. ft.6406400
Deck
Corrugated or Orthotropic Decksq. ft.2,5847001,0008840
Wearing Surfacessq. ft.2,5842,08450000
Steel Protective Coatingsq. ft.2,5847001,0008840
Bearings
Elastomeric Bearingeach1616000
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.161161000
Steel Protective Coatingsq. ft.161161000