US 6 ML over N.FK.FRENCHMAN CREEK
Map
Coordinates:
+40.61512, -102.4865340°36'54" N, 102°29'11" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | US 6 ML over N.FK.FRENCHMAN CREEK |
Structure number: | B-27-J |
Location: | 1 MI W of Paoli |
Purpose: | Carries highway over waterway |
Route classification: | Minor Arterial (Rural) [06] |
Length of largest span: | 83.0 ft. [25.3 m] |
Total length: | 169.0 ft. [51.5 m] |
Roadway width between curbs: | 40.0 ft. [12.2 m] |
Deck width edge-to-edge: | 43.0 ft. [13.1 m] |
Skew angle: | 37° |
Owner: | State Highway Agency [01] |
Year built: | 2004 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 22.5 / HS 25 [9] |
Number of main spans: | 2 |
Main spans material: | Prestressed concrete continuous [6] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: May 2017
Good/Fair/Poor Condition: | Good |
Status: | Open, no restriction [A] |
Average daily traffic: | 1,600 [as of 2011] |
Truck traffic: | 21% of total traffic |
Deck condition: | Good [7 out of 9] |
Superstructure condition: | Good [7 out of 9] |
Substructure condition: | Good [7 out of 9] |
Structural appraisal: | Better than present minimum criteria [7] |
Deck geometry appraisal: | Better than present minimum criteria [7] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8] |
Scour condition: | Bridge foundations determined to be stable for assessed or calculated scour condition. [5] |
Sufficiency rating: | 98.9 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
May 2017 | Good | Good | Good | Good | 1600 | 98.9 |
May 2015 | Good | Good | Good | Good | 1600 | 98.9 |
May 2013 | Good | Very Good | Good | Very Good | 1600 | 98.9 |
May 2011 | Good | Very Good | Good | Very Good | 1500 | 98.9 |
April 2009 | Good | Very Good | Good | Very Good | 1500 | 98.9 |
June 2007 | Good | Very Good | Good | Very Good | 1500 | 98.9 |
August 2005 | Good | Excellent | Excellent | Excellent | 1576 | 98.9 |
January 2004 | Good | Very Good | Very Good | Very Good | 1576 | 99.6 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Prestressed Concrete Girder/Beam | linear ft. | 664 | 632 | 32 | 0 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 7,271 | 7,266 | 5 | 0 | 0 |
Wearing Surfaces | sq. ft. | 6,764 | 6,764 | 0 | 0 | 0 |
Substructure |
Reinforced Concrete Column | each | 5 | 5 | 0 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 108 | 105 | 3 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 52 | 52 | 0 | 0 | 0 |
Joints |
Strip Seal Joint | linear ft. | 86 | 0 | 86 | 0 | 0 |
Pourable Joint | linear ft. | 108 | 108 | 0 | 0 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 338 | 338 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 338 | 338 | 0 | 0 | 0 |